Fadini Hindi 880 Instruction Manual - English
Right-hand opening
Hindi 880 installed
CUT to get
a suitable opening
for cable leading
STUD
for fixing the cap
95°
90°
The two gate stops in
open and closed positions
ARE NOT INCLUDED
!
INSTALLING THE GATE STOP "PROVIDED BY THE INSTALLER"
PIC. 17
Gate post line
Gate stop
Gate stop in closed position
to take the electric lock bolt
Gate stop
FITTING THE PROTECTION CAP
PIC. 18
RED
BLUE
RED
YELLOW/GREEN
Rear fixing plate
to weld
PROTECTION CAP
with opening
ATTENTION:
the electric power cable must be
ALWAYS positioned along the side of the rear
"fixing plate" between the bolt and the actuator rear
casting (Pic.18); and it must be pulled into the
cable lead and through the hole in the
= PROTECTION CAP = (Pic.19).
!
4 x 1.0
FITTING THE COVER AND THE REAR CAP
Rear fixing plate
CURVE the electric
cable through
Left-hand Opening
Hindi 880 installed
CUT to get
a suitable opening
for cable leading
4x1.0mm
2
power
supply cable, included
IMPORTANT
Connect all the
cables to GROUND
!
PIC. 19
COMPLETE
2 x grommet
nuts
Cover end plug
Cover
Tie rods
Front fixing plate
Oil-hydraulic actuator
Valve block
including max. / min.
pressure valves and
manual realease
English