Fadini Hindi 880 Instruction Manual - English
Switch setting
DIP-SWITCH:
1
4 5 6 7 8
2 3
ON
OFF
1= ON 1
st
pair Photocells. Stop in Opening cycle
2= ON Radio. No reverse in Opening cycle
3= ON Automatic Closing
4= ON Pre-flasing
5= ON Radio. Step by step, stop in between
6= ON Pedestrian opening of one gate, gate in closed position
7= ON Stroke Reversing Mode on pulsing to Open, gate closed
8= ON No Gate Delay on Opening. Both motors start together
12 13
1
2
1
DIP-SWITCH 1 (only 1
st
pair photocells):
ON: Photocells stop gates on opening and
reverse on closing once obstacle is removed
OFF: Photocells do not stop gates on opening
and reverse on closing in case of obstacle
TERMINAL BOARD -
Electronic board
low voltage
Photocells:
1
2
3
4
5
6
7
8
9 10
11 12 13 14 15
Receiver
Projector
1
st
pair Photocells (the ones fitted on to the gate posts),
controlled by Dip-Switch 1.
2
nd
pair Photocells (the ones fitted inside the gateway),
always stop the gates on opening and reverse travel direction
on closing once obstacle is removed
NC CONTACT
2
nd
pair
PHOTOCELLS
NC CONTACT
1
st
pair
PHOTOCELLS
24Vac OUTPUT(MAX LOAD:
2 PAIRS PHOTOCELLS
1 RADIO RECEIVER)
Terminal board - Elpro 13 exp -
3
S
TO
P
NC
OPEN
NO
CLOSE
NO
Switch with custom-
-coded key:
4
5
6
COMMON
F
A
D
I N
I
Lock barrel
EUROPEAN PROFILE
F
A
D
I N
I
Lock barrel
UNIVERSAL PROFILE
2
ON: No reversing in opening
OFF: Each pulse reverses travel
DIP-SWITCH 2:
ON: Step by step, stop in between
5
OFF: Normal functioning as pre-set
DIP-SWITCH 5:
7
3
COMMON
RADIO
RECEIVER
NO
Radio contact:
- Open/Close (normal)
each pulse reverses
gate travel direction
- Step by step
stop in between
Electric lock:
10
9
12V AC, 15VA OUTPUT
ELECTRIC LOCK
POWER SUPPLY
Device to mechanically hold the gates in closed position
recommended with gates wider than 2 meters and in case
non locking actuators are fitted.
Time of activation: on powering for 2 seconds, 100ms in
advance against gate motion.
Gate movement signalling:
1
1
24V 3W max
Indication light
8
COMMON
Light On = Gate open
Light Off = Gate closed
Flashing 0.5s (fast) = Gate closing
Flashing 1s = Gate opening
14 15
Safety contact:
NC SAFETY
CONTACT
Microswitch fitted to the box lid.
If not used, link out the terminals
14 and 15.
Elpro
•
13 exp
IMPORTANT
Connect all the
- yellow/green - cables
to GROUND
!
14 15
English
19