Australia
screws and loosen the inner pair. Fit the splash over the
inner screws and then refit the outer two screws. (see
figure).
Fit the Handles
(Classic model only)
Remove the 4mm Allen screws from the doors with the
hexagon key tool. Use the screws to fit the door handles.
The handles should be above the fixings.
Remove the 4mm Allen screws from the top corners of the
facia and fix the front handrail in position.
Electrical Connection
This appliance must be installed by a qualified
electrician to comply with the relevant regulations and
also the local electricity supply company requirements.
Make sure that the mains characteristics (voltage, nominal,
power, etc.) match the ratings indicated on the data plate
affixed to the lower right hand cooker upright (remove
storage drawer). The cooker is preset for a single-phase
earthed electrical connection. It is essential to install a
multi-pole circuit breaker that completely disconnects the
appliance from the mains, with a minimum contact break
distance of 3mm.
WARNING: THIS APPLIANCE MUST BE EARTHED
The appliance must be connected to an efficient earthing
circuit. If the electricity network is not equipped with an
earth connection, then it must be installed separately in
compliance with local regulations. Earthing is a safety
measure required by law, and must be performed with
particular care by a qualified technician, who must also
check that the electricity supply characteristics are correct.
The cable size used should be suitable for the appliance
load and in accordance with local regulations. Please note
the maximum cable sizes are 6mm
2
for the screw terminals
and 10mm
2
for the 3 pronged links.
Access to the mains terminal is gained by removing the
electrical terminal cover box on the back panel. Connect
the mains cable to the correct terminals for your electrical
supply type (see fig.). You may need to move the links to
suit you connection type. Check that the links are correctly
fitted and that the terminal screws are tight. Secure the
mains cable using the cable clamp.
This shows the single-phase connection.
These appliances are of type X with regard to protection
against over heating of the surrounding surfaces.