Fetco CBS-2131 XTS User Manual - page 14
14
Error Codes
Æ
Contact specialized personnel for error codes
Code Description
Possible Cause
Corrective Action
How to Clear
Error Codes
001
Software error-error on start
up or corrupted software
Improper start-up
or shutdown
Restart , if still fault: reload
software
050 Shorted temperature probe Probe failure.
Replace probe.
051 Open temperature probe.
Bad probe
connection, or
probe failure.
Check all connections.
Replace probe if necessary.
100
Initial Fill Error. Initial fill
time was more than 11
minutes after power up.
Water supply flow
rate is too low.
Watch for short potting
during brew cycle.
Investigate cause of low flow
rate. (Clogged water filter...)
101
Error on refill
Tank did not refill within 3
minutes.
Water supply flow
rate is too low.
Watch for short potting
during brew cycle.
Investigate cause of low flow
rate. (Clogged water filter…)
102
Unwanted fill;
Occurs between brews
when the fill valve
operates.
Possible leak in
tank, fitting, or
valve
Check for internal leaks
107
Lower liquid level probe
Fault
-Tank not filling
-Orange wire to
temperature probe
disconnected
-Very pure water
Occurs after prefill
-Low probe is uncovered
-Wires are reversed
-Set LLC sensitivity to HIGH
see MENU—GENERAL-LLC
201
Heater open, high limit
thermostat, or Solid State
Relay (SSR) fault
Failure of: heating
element,SSR,high
Limit or low voltage
Check and replace heating
elements if necessary.
255 Touch pad error
Usually from longer
than 2 min contact.
Or faulty reassembly
after service
Restart, if still fault: reload
software. If mechanical:
reassemble correctly
INSERT
BREW
BASKET
Brewbasket must
be in place
Insert brewbasket
TO CLEAR FAULT,
Make repairs as required
Below is the only way to
clear error codes
1) Enter
“PROGRAMMING”
2)Scroll left to “OTHER”
3)Scroll down to
“ERROR CODES”
4)Scroll down to “Display
Errors”
5)Scroll left to “Reset
Errors”
6)Scroll down to “Reset”
7)Follow directions
shown on screen.
Merely toggling ON/OFF
switch will not clear error
codes.
Error codes must be
cleared by entering
PROGRAMMING and
using the menus!
! Æ Never attempt to defeat or override a brew basket-locking feature
Regular 1
3.00
06:00
Decaf 1
3.00
06:00
Decaf 2
3.00
06:00
Regular 2
3.00
06:00