Fetco CBS-2131 XTS User Manual - page 21
21
Electrical-General
1. All FETCO brewers require Ground. Installation without ground may cause a hazard.
2.
The electrical diagram with universal wiring instructions is located on the inside of the lower cover.
3. The installation must comply with applicable federal, state, and local codes having jurisdiction at your location. Check
with your local inspectors to determine what codes will apply
Electrical Connection
1. The CBS-2130XTS series models requires hardwire to the terminal block to a 2-wire, grounded service (illus. 1)
2. Verify that the actual voltage at the electrical service connection is compatible with the specifications on the brewer’s
serial number label. Make sure the electrical service match the current draw of the equipment.
3. Plug in unit if the equipment has an attached cord & plug, or, wire into circuit for terminal block units. Note that the
plug is NEMA 5-15P or NEMA 5-20P (domestic). If unit is corded without plug, professional installer MUST size and
install appropriate plug (also termed PLUG-CAP
4. Most CBS-2131XTS equipment is factory equipped with a 120 V cord and plug. Some CBS-2131XTS and all CBS-
2132XTS have a terminal block for connecting the incoming power wires. Consult local codes to determine if a cord
and plug can be installed on factory supplied terminal block equipment, or if the unit must be hard wired.
5. Access the terminal block for electrical connection by removing the pullout service module on the lower back.
6. A fused disconnect switch or circuit breaker on the incoming power line must be conveniently located near the brewer,
and its location and markings known to the operators.
7. The temperature and water tank fill level are pre-set at the factory. There is no need to turn off the heaters during the
installation process. The heaters are disabled by the control board until the tank is full of water. The heating process
will start automatically when the tank has filled.
8. The body of the brewer must be grounded to a suitable building ground.
9. If Cord Connected: Do not use multiple taps for the plug. Consult local codes to determine if a single circuit is
required for the cord and plug installed. Do not use extension cords for commercial food equipment.
10. All covers, removable panels and electrical connections must be secured in-place within the unit to meet national and
local standards.
CBS-2131XTS
120 volt models
(some)CBS-2131XTS and (all)CBS-2132XTS
208-240 volt models
Factory Configuration:
Attached cord 120 VAC, 3 wires
L1 L2
N
GROUND
LUG
CORD WITH
NEMA 5-15P or 5-20P
or without PLUG
L2 - NOT USED
For 120 volt
GROUND WIRE
!MUST BE INSTALLED!
Factory Configuration:
Terminal block for professional installation
L1
L2
N
GROUND LUG
GROUND WIRE
!MUST BE INSTALLED!
N
NOT USED
208-240V
120V
120V
NOTE: ÆNEW FETCO CONFIGURATIION METHOD!
Warning: To prevent
electrical shock, this
unit must be properly
grounded.
WARNING—DANGER
Do not plug-in or electrically energize
this equipment, or attempt operation
without all covers in place and all
screws fastened
.
G
W
G
W
NEMA PLUG CONFIGURATION
NEMA 5-15P NEMA 5-20P
Tank Drain
Utility slide
on back
of brewer
Power
Switch
Electrical
Connection
Water
Supply
Connection