FRANCO UCP Instruction Manual For Use And Maintenance - page 17
FRANCO srl Manual of use and maintenance UCP
17
4 - MAINTENANCE
Before undertaking any maintenance,
disconnect the device from the electricity and water supply!
Periodically check that the amount of water reaching the slinger is correct, if necessary adjust the flow regulator.
Keep clean the disks, the tank and the internal components, and prevent the accumulation of dirt on the lid.
4.1 Cleaning the disk
Keep the disk clean to avoid the formation of calcareous deposits or accumulation of dirt, which could cause an
increase in vibration or coarse nebulization.
To clean the rotating disk, simply use a soft damp cloth and a non-toxic and solvent free detergent, rubbing and
being careful to avoid excessive pressure.
Do not use solvents.
The fixed disk should be cleaned with a small brush with stiff bristles, rubbing the teeth, being careful not to
damage them.
Any eventual limescale can be removed with muriatic acid diluted with water.
4.2 Cleaning the tank
Periodically clean the water tank.
To access it, unscrew the two screws on the lid and pull gently, grasping the appropriate grip.
To ease the cleaning, it is possible to remove the float’s sphere and the pump.
To remove the sphere it is necessary to unscrew the plastic arm of the float (Fig. 4.1).
To remove the pump it is necessary to operate while holding with a no. 13 spanner the stop ring in which the
pump is placed and pull gently the pump up to complete removal.
Once all these operations have been completed, it is possible to clean the interior of the tank with a cloth or a
sponge, rubbing gently on the walls. Do not use solvents.
It is necessary to periodically check the functioning and the cleanliness of the pump and the float.
Each 2-3 months clean the internal parts of the pump with warm water.
Fig. 4.1
Fig.4.3
4.3 Changing the pump
Remove the two cover screws using a cross or “Phillips” screwdriver Remove the lid by pulling it, grabbing the
appropriate grip between thumb and forefinger. Unscrew the plastic arm of the float as shown in Fig. 4.1.
Operate holding the stop ring with a no. 13 spanner in which the pump is placed and pull the pump gently up to
complete removal. Remove the nylon pawl from the entrance of the connection to the removed pump and snap it
onto the new pump. Repeat the sequence backward, being careful to reposition the float so that the water level
inside the tank covers the pump completely.