6 - PROBLEMS AND SOLUTIONS
Before undertaking any maintenance,
disconnect the device from the electricity and water supply!
PROBLEM
CAUSE
SOLUTION
The device does not
start.
The power supply is not
plugged.
Verify the electrical connection, or the
functioning of the mains itself.
The motor power supply
is disconnected.
Check the power supply line of the motor.
The spinning disk
does not turn but the
water is re-circulated
by the pump.
The motor is broken.
Contact qualified and authorized
personnel to replace the motor.
The pump’s water supply
is unplugged.
Check the water supply line of the pump.
The circuit of water
supply is disconnected.
Check the water supply pipe and the
atomizing control valve.
The pump is clogged.
Clean the tank and accurately clean the
pump.
The pump is full of air.
Disconnect the 3/8” tube from the valve,
allowing the vent of the hydraulic circuit.
Accurately clean the pump.
The pump is broken.
Contact qualified and authorized
personnel to replace the pump.
The spinning disk
turns but the water is
not atomized.
The float does not fill the
tank.
Test the functioning of the float, in case of
damage or failure contact qualified and
authorized personnel to replace it. .
The fixed disk is dirty.
Clean the fixed disk.
The spinning disk is too
distant from the fixed
disk.
Verify that the distance between the fixed
disk and the spinning disk is around 4mm;
add or remove spacers to adjust the
distance.
The atomization is
coarse.
The nozzle is badly
positioned.
Verify the position of the nozzle.
The spinning disk is
broken.
Contact qualified and authorized
personnel to replace the spinning disk.
The machine
vibrates.
The motor is broken.
Contact qualified and authorized
personnel to replace the motor.