Garador Garamatic 10 Instructions For Fitting, Operating And Maintenance - page 43
TR10A108 RE / 05.2012
43
Display of Errors/Warnings and Operating Conditions
17
Display of errors and warnings
17.1
Display
Error/warning
Possible cause
Remedy
Reversal limit cannot be set
An obstacle was in the way when the
SKS/VL reversal limit was set
Remove the obstacle
The position of the reversal limit is
> 200 mm before the Close end-of-
travel position
Pressing the buttons
or
acknowledges
the error.
Select a position < 200 mm before the Close
end-of-travel position
Partial opening height
cannot be set
The partial opening height is too
close to the Close end-of-travel
position (≤ 120 mm slide travel)
The partial opening height must be higher
Safety equipment
(photocells)
No photocell is connected
Connect a photocell or activate menu 60
The light beam is interrupted
Adjust the photocell
The photocell is defective
Exchange the photocell
Power limit in Close direction The door is too sluggish or does not
move smoothly
Correct the door travel
Obstacle in door area
Remove the obstacle and teach in the
operator again, if necessary
Static current circuit open
The wicket door is open
Close the wicket door
The magnet has been fitted the
wrong way
Fit the magnet correctly (see the instructions
for the wicket door contact)
The testing result is not OK
Exchange the wicket door contact
Stop UAP pressed
Power limit in the Open
direction
The door is too sluggish or does not
move smoothly
Correct the door travel
Obstacle in door area
Remove the obstacle and teach in the
operator again, if necessary
System error
Internal error
Restore the factory setting (see section 12),
teach in the operator again or exchange, if
necessary
Travel time limit
The belt is torn
Exchange the belt
The operator is defective
Exchange the operator
Communication error
Communication with the additional
print is faulty (e.g. UAP 1, ES 1,
ES 2, EF 1)
Check the connecting leads and exchange,
if necessary
Check the additional print and exchange,
if necessary
Travel command not
possible
The operator has been blocked for
the control elements and a travel
command was given
Release the operator for the control elements
Check the connection of the IT 3b
Closing edge safety device
The light beam is interrupted
Check the transmitter and receiver and
exchange, if necessary, or exchange the
complete closing edge safety device
8k2 resistance contact strip
is defective or not connected
Check the 8k2 resistance contact strip or
connect to the operator via the 8k2-1T
decoder unit
No reference point
Power failure
Move the door to the Open end-of-travel
position
Power limit has been triggered 3 x
in a row in the Close direction
The operator has not been
taught in
The operator has not been taught in
yet
Teach in the operator (see section 5)
Maintenance display flashes
during each door run.
No error
The maintenance interval set by the
fitter has been exceeded.
Have the door system inspected and
maintained by a qualified person in
accordance with the manufacturer's
specifications.
ENGLISH
www.thegaragedoorcentre.co.uk
0800 525 442
www.thegaragedoorcentre.co.uk