Page 5-18
400W Series Installation Manual
Rev. G
190-00356-02
TO-FR (LAT)
Selection Verify
That:
FROM
The FROM flag is in view.
Hide
The TO/FROM flag is hidden.
TO
The TO flag is in view.
SELECTED COURSE
Select 150° on the CDI/HSI that is connected to the 400W Series VOR/LOC/GS OBS inputs. The
SELECTED COURSE field should indicate near to 150° and a Calibrate to 150°? field appears.
Selecting this field calibrates the 400W Series to match the input source. Verify OBS operation by
checking that the course displayed on the 400W Series is within 2° of the selected course. Do this at 30°
intervals around the OBS card.
DME CHNL MODE
This configuration allows you to set the format for DME tuning data output.
Selection Description
King serial
King Serial DME tuning data
Parallel 2x5
2 of 5 parallel DME tuning.
Parallel BCD
Shifted BCD (Binary Coded Decimal) parallel DME tuning
Parallel slip
Slip-code parallel DME tuning
Narco 890/891
2 of 5 parallel DME tuning, compatible with the following DME units:
Narco DME 890
Narco DME 891
ARC (Cessna) RTA-476A