Golden Vantage 1801(A) Installation Instructions Manual - Troubleshooting
13
Check if the range hood has been plugged in, make sure that all power has been turned
back ON, fused not blown and all electrical wiring are properly connected.
Swap out light assembly to working ones to determine whether it is caused by a
defective bulb.
2. The range hood vibrates when the blower is on:
The range hood might not have been secured properly on the ceiling or wall.
3. The blower or fan seems weak:
Check that the duct sized used is at least 8” or 3-1/4 x 10”. Range hood WILL NOT
function efficiently with insufficient duct size. For example: 10” duct over 8” hole and
loosely secured.
Check if duct is clogged or if damper unit (half-circular flapper) is not installed correctly
or opening properly. A tight mesh on a side wall cap unit might also cause restriction to
the air flow.
4. The lights work but the blower is not spinning at all. It’s stuck or it’s rattling.
The blower might be jammed or scraping the bottom due to shipping damage. Please
contact us immediately.
5. The hood is not venting out properly.
Make sure the distance between the stove top and the bottom of the hood is within
27”-30” in distance.
Reduce the number of elbows and length of duct work. Check if all joints are properly
connected, sealed, and taped.
Make sure the power is on high speed for heavy cooking.
NOTE: For all other inquiries, please contact us.
Troubleshooting
1. If the range hood or halogen light does not operate after installation: