Hahnel modus 600rt Instruction Manual - page 12
GB
GB
22
Modus 600RT
Modus 600RT
23
Wireless Settings
You can switch between normal flash and wireless flash. For normal
flash shooting, be sure to set the wireless setting to OFF
Master Unit Setting
Slave Unit Setting
Master Unit Flash ON/OFF
You can switch ON or OFF the “Master” unit flash that is controlling the
wireless “Slave” units. When Master flash is ON, it will flash as group M
Setting the group mode - TTL / M / OFF
From the “Master” Modus Speedlight each Group M (master
speedlight) / A / B / C “mode” setting can be adjusted individually.
Press <
> button
so that
<
> and <
MASTER
> are
displayed on the LCD panel.
Press <
> button
so that <
> and <
SLAVE
> are
displayed on the LCD panel
1. Press Function Button 4 <
Gr
> and one Group
M/A/B or C will be highlighted
2. Press Function Button 4 <
Gr
> again until <
M
> is highlighted
3. Press Function Button 3 <
MODE
> until <
M
> is
<--->. The master speedlight
is now OFF
1. Press Function Button 4 <
Gr
>
• Keep pressing Button 4 <
Gr
> until <
A
> is
highlighted
2. Press Function Button 3 <
MODE
>
and select the
desired Mode TTL
Manual
1. If you have a Viper TTL, start
the DCM matching with the
Viper TTL
• Turn < ON > the Viper TTL
transmitter whilst holidng
down the < test > button
and release
after 2 seconds
• The Viper LCD will show <
Co di ng>
2.
If you are not using a Viper
TTL and only wish to DCM
several Modus 600RT, then
use any Modus 600RT as the
Master unit
• Press
1>
whilst turning < ON > the
power to the Modus 600RT
• A green LCD on the
Modus 600RT will show
<
MASTER
>
3. Press
whilst turing < ON > power to
the slave Modus 600RT
Setting the DCM
(Digital Channel Matching)
Initialy the Modus 600RT wireless 2.4GHz is set to a general “open
channel” and can be used as it is. To avoid interference with other
wireless flash systems we recommend to DCM (digital channel match)
your Modus 600RT speedlight’s and Viper TTL.
Master – Viper TTL or Modus 600RT
Slave - Modus 600RT
OK
4. A red LCD will show “Slave
OK”. This slave Modus 600 RT
is now DCM matched
5.DCM match the same way,
any additional slave Modus
600RT while the Master is
still on
Once all slave units are DCM matched, reboot all master and slave’s by
turning OFF/ON
• Once all devices are DCM matched they will memorieze the unique ID
even it power is removed. Therfore you only need to DCM your set once
• If you add more speedlights or Viper TTL units to your range then you
need to carry out the DCM matching for all your units again