Jablotron 100 User Manual

Summary of 100

  • Page 1

    User manual mlj57205 - en user manual - desky.Indd 1 20.9.2014 12:23:18.

  • Page 2

    1 1. Introduction 2 2. Operating the jablotron 100 system 2 2.1 using the system keypad 5 2.1.1 alarm setting 8 2.1.2 alarm unsetting 8 2.1.3 partial alarm setting 9 2.1.4 terminating a triggered alarm 9 2.1.5 section control from the keypad’s display menu 10 2.2 operating the system with a keyfob 1...

  • Page 3

    2 2 1. Introduction thank you for choosing the jablotron 100 security system. This system is a unique fl exible indoor solution for commercial and home security that offers the use of both wired and wireless devices. The jablotron 100 is very easy to control. Simplicity of control consists of two ste...

  • Page 4

    3 keypad code authorization authorization with a user code is done by typing a valid code into a keypad or with an rfid tag. It’s possible to use 4, 6 or 8-digit codes in the system. The system can be confi gured to be used with or without prefi x codes. Code with a prefi x: nnn*cccc meaning: nnn is th...

  • Page 5

    4 code without a prefi x: cccc meaning: cccc cccc is a 4, 6 or 8-digit code. Allowed codes… from 0000 to 99999999 default control panel code administrator: 1234; 123456; 12345678; the security of access codes, contactless rfid devices and remote controls a control panel enables each user to be assign...

  • Page 6

    5 ways of operating the jablotron 100 on-site: a system keypad a system keyfob a computer using a usb cable and the j-link software remotely: a computer via the myjablotron web interface a smart phone application a telephone using the voice menu a mobile – via sms a computer via the internet using j...

  • Page 7

    6 the various types of access modules and their combinations: when unsetting the alarm using the segment buttons, user authorization is always required. When setting the alarm and controlling automated processes using the segment buttons, user authorization is optional for each segment. A user can b...

  • Page 8

    7 structure and description of the internal lcd keypad menu 2. Operating the jablotron 100 system cancel warning indication section control event memory setting prevented bypassed detectors faults in system system status settings display setting allows you to cancel alarm/unsuccessful setting indica...

  • Page 9

    8 2.1.1 alarm setting while setting the alarm, if any detector is triggered (e.G. An open window) the system will react (based on the system confi guration) in one of the following ways: a detectors will guard automatically after they switch to standby mode (default setting) a the system will optical...

  • Page 10

    9 duress access control provides unsetting of the system in a special mode. The system seemingly unsets, however it triggers a silent panic alarm, which is reported to selected users (including arc). Unsetting under duress is executed by adding 1 to the last number in a valid code. Contact your serv...

  • Page 11

    10 a triggered alarm in progress is indicated by a rapidly fl ashing red segment button and a backlit indication button. You need to authorize yourself using the keypad in order to terminate the alarm. The section remains set, a rapidly fl ashing red segment button indicates the alarm memory. Indicati...

  • Page 12

    11 the keyfob buttons can be blocked to prevent accidental pressing. A command will be sent out when a button is pressed repeatedly. A low battery is indicated acoustically (with 3 beeps) and optically with a yellow fl ashing led after pressing a button. For more information, consult confi guration of...

  • Page 13

    12 2.5 operating the system using the internet and myjablotron the jablotron 100 system can be easily and conveniently operated using your computer via the internet and the myjablotron web interface, which is accessible from www.Myjablotron.Com. For more information about this web interface please s...

  • Page 14

    13 a the event history is not available a the system doesn’t send event notifi cations (sms, email, push messages) a virtual system keypads are not available a a detector’s photo gallery and photos upon request are not available a thermometers, electricity meters and other supported automation device...

  • Page 15

    14 it’s possible to set / unset the system using icons on the lower bar of the program or with the “status” buttons in the “section” tab. If a keypad with at least one controllable segment is used in the system, then it is possible to set/unset the system in j-link using an on-screen virtual keypad ...

  • Page 16

    15 only the system administrator or service technician can block a user. One method of taking away access rights is by choosing settings / users / user / bypass and selecting “yes” on the lcd keypad. Another option is to locally or remotely block a user through the j-link software by clicking on the...

  • Page 17

    16 the system administrator and the service technician can add, change and delete rfid cards/tags from both the lcd keypad menu and j-link. 4.3 changing a username or phone number if the system is set up with prefi x codes, users can add, change or delete their telephone numbers or change their name ...

  • Page 18

    17 5.3 logging into myjablotron (web/smartphone) all system events can be viewed after logging in the myjablotron web/smartphone interface. The account shows history in a range which corresponds with the user’s permissions. The myjablotron web interface is a unique service that allows on-line access...

  • Page 19

    18 jablotron alarms a.S. Hereby declares that these control panels ja-101k, ja-101k(-lan)(3g) a ja-106k (-3g) meet the basic requirements and other relevant provisions of the directive no. 2014/53/eu, 2014/35/eu, 2014/30/eu and 2011/65/eu. You will fi nd the original declaration of conformity at www....

  • Page 20

    19 bus / wireless devices the main hub of the security system is its control panel. It can communicate with all devices in two ways: using the bus, i.E. Using data cables within the guarded premises or part thereof; or wirelessly using radio communication. Bus devices are powered by the control pane...

  • Page 21

    20 notes: for questions and further information contact your installer. Mlj57106.

  • Page 22

    Www.Jablotron.Com www.Jablotron.Com 8 595614 114110 mlj57205 - en user manual - desky.Indd 1 20.9.2014 12:23:18.