8. TECHNICAL SPECIFICATIONS
PARAMETR
JA-101K (-LAN) (-LAN3G)
JA-106K (-3G)
Control panel power supply
(replacement fuses are pac-
kaged with the control panel)
~ 230 V / 50 Hz, max. 0.1 A,
together with T200 mA fuse,
~ 110 V to 120 V / 60 Hz,
max. 0.2 A, together with T400 mA fuse,
protection class II
~ 230 V / 50 Hz, max. 0.2 A,
together, with T400 mA fuse,
protection class II,
Back-up battery
12 V; 2.6 Ah (lead gel)
12 V; 7 to 18 Ah (lead gel)
Maximum battery charging time
72 h
72 h
Max. number of devices
50
120
LAN communicator
Ethernet interface (only LAN version)
Ethernet interface
Dimensions (mm)
258 x 214 x 77
357 x 297 x 105
Weight
1250 g
2500 g
Reaction to invalid code entry
ALARM AFTER 10 WRONG CODE ENTRIES
Event memory
APPROX. 7 MILLION LATEST EVENTS, INCL. DATE AND TIME
Power supply unit
TYPE A (EN 50131-6)
GSM communicator
850 / 900 / 1800 / 1900 MHz
GSM communicator 3G
850 / 900 / 1800 / 1900 / 2100 MHz
Environment
class II, in acc. with EN 50131-1
Operating temperature range
-10 to +40°C, average humidity up to 75%
Security level
grade 2 according to EN 50131-1, EN 50131-3, EN 50131-6, EN 50131-5-3
Operating frequency
(with the JA-11xR module)
868.1 MHz
Radio emissions
ETSI EN 300220 (module R), ETSI EN 301 419-1, ETSI EN 301 511 (GSM)
EMC conformity
EN 50130-4, EN 55022, ETSI EN 301 489-7
Safety conformity
EN 60950-1
Operational conditions
ČTÚ VO-R/10, ERC REC 70-03, ERC DEC (98) 20
Certifi cation body
TREZOR TEST (JA-101K, JA-101K-LAN JA-106K), INCERT T014(A) (JA-101K, JA-106K)
Caller identifi cation conformity
ETSI EN 300 089