Jablotron 100 User Manual - page 11
10
A triggered alarm in progress is indicated by a rapidly fl ashing red segment button and a backlit
indication button. You need to authorize yourself using the keypad in order to terminate the alarm.
The section remains set, a rapidly fl ashing red segment button indicates the alarm memory. Indication will
keep on fl ashing even after the system has been unset.
If the alarm memory indication was activated during your absence, search for the cause of the alarm
in the event history and be very careful when entering and checking the premises or wait until the security
agency arrives (provided your system is connected to an Alarm Receiving Centre).
The segment alarm memory indication remains on until the system is set once again. Alternatively, it can
be cancelled by unsetting the system one more time. Alarm indication can be also cancelled from a keypad
with an LCD display in the Main menu – Cancel warning indication.
Indication of a triggered tamper alarm can be terminated only by a Service technician.
Note: When using the “Default” system profi le, it’s possible to fi rst select a particular action by pressing
a segment button and then confi rm it by authorization using the keypad.
Terminating an alarm using a remote control will also unset the corresponding section.
2.1.5 SECTION CONTROL FROM THE KEYPAD’S DISPLAY MENU
Statuses of sections are displayed in the left top part of the display.
A fully set section is shown by a number in a rectangle fi lled with black colour.
A partially set section is depicted by a framed number.
Control from the keypad menu:
a
Authorization by a valid code or an RFID chip
a
Enter the menu by pressing ENTER
a
Section Control → ENTER
a
Select the desired section using arrows
a
Pressing ENTER repeatedly will change between section statuses
(partially set / set / unset)
a
Press ESC to exit the menu
2.2 OPERATING THE SYSTEM WITH A KEYFOB
Keyfobs must be enrolled into the system by the installer. The keyfob can be linked to specifi c users, which
will prevent SMS text message notifi cation to the user who is interacting with the system at the moment
(if notifi cation parameters are set up in this way). The keyfob can provide either bi-directional communication,
confi rming the execution of a command with a coloured indicator light, or one-way without any confi rmation.
Keyfobs control and indicate battery status and are equipped with optical and acoustic indication.
Bi-directional keyfob
The button functions are differentiated by lock icons. The closed lock icon sets
programmed sections; the opened lock icon unsets them. Correct command execu-
tion is confi rmed by an LED light; unsetting – green, setting – red. A communication
fault (out of the control panel’s range) is indicated by a yellow LED light fl ashing
once. The buttons with symbols of full and empty circles can control another
section. Buttons of the keyfob can also be confi gured to control PG outputs in
different modes: the fi rst button switches on/ the second switches off, each button
can have an individual function when impulse or change functions are used.
For more functions, it’s possible to press two buttons at the same time. This way
a 4-button keyfob can have up to 6 individual functions or one PG status output (e.g.
turn the lights on and off), alternatively two PG outputs (e.g. a garage door and door lock).
If the system is confi gured to Set after confi rmation (chapter 2.1.1) the detector will indicate unsuccess-
ful setting with a green LED light if a device is triggered. It’s necessary to confi rm setting by pressing
the lock button again. A set section will be confi rmed by a red LED light.
2. OPERATING THE JABLOTRON 100 SYSTEM