  • Page 1

    H0569300d installation and op er a tion man u al installation and operation data danger risk of electrical shock or electrocution. The electrical supply to this product must be installed by a licensed or certifi ed electrician in accordance with the national electrical code and applicable local code...

  • Page 3

    Page 1 table of contents section 1. General information ..................3 1.1 introduction ......................................................... 3 1.2 consumer information and safety ...................... 3 1.2.1 spa/hot tub safety rules ............................ 3 1.2.2 swimming pool ener...

  • Page 4

    Page 2 figures and tables figure 1. Jandy ae-ti heat pumps dimensions .......6 figure 2. Anchor clamp positions .............................9 figure 3. Anchor clamp installation ..........................9 figure 4. Standard plumbing layout ....................... 11 figure 5. Plumbing for heating ...

  • Page 5

    Page 3 throughout the manual, safety warnings and cautions are identified by the “ “ symbol. Be sure to read and comply with all of the warnings and cautions. 1.2.1 spa/hot tub safety rules warning the u.S. Consumer product safety commission warns that elevated water temperature can be hazardous. Co...

  • Page 6

    Page 4 1. Spa or hot tub water temperature should never exceed 104°f (40°c). One hundred degrees fahrenheit (100°f [38°c]) is considered safe for a healthy adult. Special caution is recommended for young children. 2. The drinking of alcoholic beverages before or during spa or hot tub use can cause d...

  • Page 7

    Page 5 dealer or directly to the factory. Claims must include the heat pump serial number and model (this information can be found on the rating plate), installation date, and name of the installer. Shipping costs are not included in the warranty coverage. The warranty does not cover damage caused b...

  • Page 8

    Page 6 figure 1. Jandy ae-ti heat pumps dimensions 1.7.3 technical specifi cations model ae1500t ae2000t ae2000t--263 ae2500t ae2500t--263 ae3000t ae3000t--263 voltage/frequency/phase 208-230/60/1 208-230/60/1 208-230/60/3 208-230/60/1 208-230/60/3 208-230/60/1 208-230/60/3 output 73,000 btus 100,00...

  • Page 9

    Page 7 attention lorsque l’équipement d’une piscine est situé sous la surface de l’eau, une fuite provenant de n’importe quel élément peut causer une perte d’eau importante ou une inondation. Jandy pool products, inc.N’est pas responsable des pertes d’eau, des inondations ou des avaries causées par ...

  • Page 10

    Page 8 aux etats-unis, ce chauffe-piscine doit être installé á au moins 5 pieds (1,5 m) de la paroi interne de la piscine à moins d’être isolé de la piscine par une clôture, un mur ou autre barrière permanente. En estados unidos, esta bomba de calor deberá instalarse a una distancia de al menos 5 pi...

  • Page 11

    Page 9 5. Mark the position of the hole in each clamp on the equipment pad. 6. Drill a hole in the cement using a masonry drill bit, with a diameter as determined by the concrete anchor, at each of the marks on the equipment pad. The hole should be approximately 1-1/2” deep. 7. Insert a bolt anchor ...

  • Page 12

    Page 10 caution make sure that fl ow requirements and pool water turn over rates can be maintained with the installation of additional heat pumps and plumbing restrictions. Attention assurez-vous que la circulation d’eau requise soit maintenue même si des pompes d’appoints ou des éléments de plomber...

  • Page 13

    Page 11 figure 4. Standard plumbing layout a qu ap u re sensors pool pump filter pool heater from pool or spa chemical feeder to pool or spa check valve or optional chlorine generation system (jandy aquapure shown) manual bypass valve chemical loop vent for indoor installation only figure 5. Plumbin...

  • Page 14

    Page 12 figure 6. Two heat pump plumbing layout figure 7. Four heat pump plumbing layout manual bypass valve 2” pvc 3” pvc optional isolation valves from filter to pool manual bypass valve optional isolation valves from filter to pool 2” pvc 3” pvc.

  • Page 15

    Page 13 section 4. Electrical connections warning electrical shock hazard. This heat pump contains wiring that carries high voltage. Contact with these wires may result in severe injury or death. Disconnect power circuit before connecting the heat pump avertissement possibilitÉ de chocs Électriques....

  • Page 16

    Page 14 figure 8. Ae-ti single-phase electrical supply wiring diagram r bk bl r y bk br/w br br/w bk bk l 2 h3007200a ae series br r r bl y bk bk bk y bk bk bk r22 r22 bl bk o bl y 24~ 208/230~ 24~ 24~ 208/230~ 208/230~ 24~ l1 bk - black/noir/negro bl - blue/bleu/azul br - brown/marron/marron br/w -...

  • Page 17

    Page 15 r bk bl bk y bk br/w br br/w br l 3 h3007300a br r r bl y bk bk bk y bk bk bk bl 24~ bk o o y w l1 br bk bl y w y-out y c three phase line voltage monitor l1 l2 l3 y y r r l 2 o bk w bk bk bk bk r w r bk r bl w y y w w w bl ae series 208 - 230 vac three phase 60 hz wiring diagram 208/230~ 24...

  • Page 18

    Page 16 figure 11. Ae-ti heat pump front view maintain temp to time clock connection connector for high voltage wires connector for low voltage wires service access panel (4 screws) figure 10. Example of maintain temp wiring to the time clock intermatic model t104 mechanical timer (not provided with...

  • Page 19

    Page 17 figure 12a. Remote pool-off-spa connection (3-wire connection) figure 12b. Aqualink rs or remote tstat connection (2-wire connection) 4.3 bonding caution this heater must be connected to a bonding grid with a solid copper wire not smaller in diameter than 6 ga. Attention l’appareil de chauff...

  • Page 20

    Page 18 3. Press the up or down button to display remote. Press the menu button.The select remote off (default remote) appears, use the up or down button to scroll through the remote options. When you reach hi-lo-com, press the menu button to select the remote. Press pool or spa to exit the service ...

  • Page 21

    Page 19 4.5.2.3 confi gure the control panel 1. Make sure the control is in the off mode. 2. To enter the service setup mode, press and hold the menu, pool, and spa buttons for 5 seconds. Note the display will revert back to off after one minute since the last key press. 3. Press the up or down butt...

  • Page 22

    Page 20 figure 14. Main control panel clean the filter at the end of this operation before starting the heat pump. When raising the temperature of a cold pool, program the time clock to run the pump continuously. This lets the filter system and heat pump operate continuously until the water reaches ...

  • Page 23

    Page 21 you can change the temperature set point by pressing the up or down button . Repeatedly press the up or down button until you reach the desired temperature set point. After 5 seconds of inactivity, the new set point is stored in memory. When the water temperature falls to 1 degree below the ...

  • Page 24

    Page 22 desired language, press the menu button to select the language. Press pool or spa to exit the user setup mode. 5.4.2 temperature scale setup 1. Make sure the control is in the off mode. 2. To enter the user setup mode, press and hold the menu button for 5 seconds. 3. To select temperature sc...

  • Page 25

    Page 23 the pressure switch is preset at the factory for activation at 2 psi (14 kpa). This is the minimum setting for the water pressure switch and works for all basic installations as shown previously in section 3.1 and section 3.5 in this manual. Only adjust the water pressure switch if the heat ...

  • Page 26

    Page 24 section 6. General maintenance 6.1 water chemistry proper chemical balances are necessary for sanitary bathing conditions as well as ensuring your heat pump’s long life. Be sure to keep your chemical and mineral concentration levels within the values indicated in table 3. Note for spas, it i...

  • Page 27

    Page 25 6.4 inspection and service jandy heat pumps are designed and constructed to provide long performance life when installed and operated properly under normal conditions. Periodic inspections are important to keep your heat pump running safely and efficiently through the years. 6.4.1 owner insp...

  • Page 28

    Page 26 5. Check for spider webs or debris in the condensate drain; clean if necessary. 6. Conduct a normal operating cycle and observe that the unit operates properly. Section 7. Professional maintenance and service 7.1 heat pump design the jandy air energy heat pump is one of the most efficient wa...

  • Page 29

    Page 27 table 4. Heat pump troubleshouting guide section 8. Troubleshooting 8.1 troubleshooting guide the following table provides symptoms and solutions for general troubleshouting problems for the heat pump. Symptom corrective action heat pump will not start, no control board display. Breaker or f...

  • Page 30

    Page 28 8.2 diagnostics in the event a pressure switch opens or another fault condition occurs, the lcd screen will display the fault until the problem has been resolved. Please refer to the following table for the list of diagnostic conditions. Table 5. Heat pump diagnostics diagnostic condition de...

  • Page 31

    Page 29 key no. Description model no. Order part no. 1 top enclosure, jacket 1500 r3009700 1 top enclosure, jacket 2000, 2500, 3000 r3009100 2 service access panel all r3000500 3 control cover - smoked all r3000601 4 fan motor, 1/6 hp, 208 - 230 vac 1500 r3000703 4 fan motor, 1/2 hp, 208 - 230 vac 2...

  • Page 32

    Page 30 9.3 jandy ae-ti heat pumps exploded view 2 31 6 7 9 23 30 8 5 16 b 21 18 a 29 10 20 28 4 14 1 3 15 25 12 11 detail “b” detail “a” these pressure switches are installed in the refrigerant line near the compressor red wire blue wire yellow wire orange wire 17 figure 17. Jandy ae-ti heat pumps ...

  • Page 33

    Page 31 notes.

  • Page 34

    Page 32 notes.

  • Page 35

    Page 33 notes.

  • Page 36: Limited Warranty

    Limited warranty thank you for purchasing jandy ® pool and spa products. Jandy pool products, inc. (manufacturer of pool and spa heaters, air energy heat pumps, and clormatic electronic chlorine generators) warrants all parts to be free from manufacturing defects in materials and workmanship for a p...