Jandy AE-Ti Installation And Operation Manual - page 19
Page 17
Figure 12a.
Remote Pool-Off-Spa Connection
(3-Wire
Connection)
Figure 12b.
AquaLink RS or Remote TSTAT
Connection (2-Wire Connection)
4.3 Bonding
CAUTION
This heater must be connected to a bonding
grid with a solid copper wire not smaller in
diameter than 6 ga.
ATTENTION
L’appareil de chauffage doit être connecté à
une grille de mise à la terre par un fi l de cuivre
d’un diamètre de calibre minimal 6.
PRECAUCIÓN
Esta bomba de calor deberá estar conectado
a una rejilla de unión con hilo de cobre sólido,
de un diámetro no inferior a 6 ga.
The National Electrical Code and most other U.S.
codes require that all metallic components of a pool
structure, including reinforcing steel, metal fittings,
and above ground equipment be bonded together with
a solid copper conductor not smaller than 6 ga. The
heat pump, along with pumps and other pool equipment
must be connected to this bonding grid. A bonding lug
is provided on the right hand side of the heat pump to
ensure this requirement is met.
4.4
Pump Connection (Maintain Temp
Feature)
This feature allows the heat pump to turn on the
pool pump, bypassing the time clock setting, to maintain
the desired temperature. In order for the MAINTAIN
TEMP feature to be functional, a dedicated line from
the pool pump time clock to the Maintain Temp (Pump)
Relay is needed. See Figure 10.
4.5
Optional Remote Controls
Electrical wiring must be in accordance with all
applicable national and local codes and ordinances.
4.5.1
Connection to a Remote Pool-Off-
Spa Selector (3-Wire Connection)
4.5.1.1 Install the Remote Pool-Off-Spa
Selector
1.
Turn off the power to both the pool/spa control
system and the heat pump unit.
2. Remove the four (4) screws that attach the service/
access panel to the heat pump unit and the cover to
the junction box (see Figure 11).
3.
Run the wires from the pool/spa control system
into the conduit connection labeled “Low Voltage
Connection”, located on the lower right hand side
of the heat pump (see Figure 11).
4.
Connect the wiring from the pool/spa control
system to the heat pump remote control terminal
(see Figure 12a).
5.
Restore power to the heat pump and the pool/spa
control system.
4.5.1.2 Confi gure the Control Panel
1.
Make sure the control is in the OFF mode.
2.
To enter the Service Setup mode, press and hold
the MENU, POOL, and SPA buttons for 5
seconds.
NOTE The display will revert back to OFF after one
minute since the last key press.