Figure 14. Main Control Panel
Clean the filter at the end of this operation before
starting the heat pump. When raising the temperature
of a cold pool, program the time clock to run the pump
continuously.
This lets the filter system and heat pump operate
continuously until the water reaches the temperature
setting on the temperature control. When that happens,
the heat pump will automatically shut off, but the filter
pump will keep running.
5.2
Operating the Controller
Your new AE-Ti heat pump is controlled by an
advanced microprocessor based controller that provides
a sophisticated yet simple interface to operate your heat
pump for maximum efficiency and enjoyment of your
pool. To locate the control buttons, see Figure 14.
5.2.1 Off
Mode
When the control panel is turned off, the screen
displays
HEAT PUMP IS OFF
PRESS POOL OR
SPA
.
5.2.2
Pool Mode - (Normal Heat)
To enable the pool mode, press
POOL
. The
associated left green LED indicator will light and the
unit will display
SET:XXX°
.
NOTE
XXX
represents the current temperature setting
on the control. The default setting for pool
temperature is 80°F (26°C).
You can change the temperature set point by
pressing the
Up
or
Down button
.
Repeatedly press
the Up or Down
button until you reach the desired
temperature set point. After 5 seconds of inactivity, the
new set point is stored in memory.
When the water temperature falls to 1 degree
below the temperature setting
and
after a 5 minute
delay, the control will start the heat pump and the
associated right LED will light RED
.
5.2.3
Pool Mode - (Optional Maintain
Heat)
If connected, the Maintain Heat mode allows the
heat pump to monitor the temperature of the water 24
hours a day by turning the pool pump on and sampling
the water temperature. When the water temperature
drops below the programmed temperature set point, the
control will start the heat pump.
To operate in pool mode with the Maintain
Heat feature, press
POOL
, then press
MENU,
press
the
Down
button until
MAINTAIN POOL HEAT
is
displayed, press the
MENU
button.
The associated left green LED indicator will
light and the unit will display
SET:XXX°.
Change the
temperature set point by pressing the
Up
or
Down
button until the desired set point is displayed. After
5 seconds of inactivity, the new set point is stored in
memory.
5.2.4
Spa Mode - (Normal Heat)
To enable the spa mode, press
SPA
. The
associated left green LED indicator will light and the
unit will display
SET:XXX°
.
NOTE
XXX
represents the current temperature setting
on the control. The default setting for spa