Jandy JXi 200 Installation And Operation Manual - Warning
Page 21
ENGLISH
Jandy
®
Pro Series, JXi
™
Gas-Fired Pool & Spa Heater
|
Installation & Operation Manual
Sweep Elbow
Union Nut
Union Nut
Union Tailpiece
Union Tailpiece
Cut Pipe
Cut Pipe
O-Ring
O-Ring
O-Ring
Drain Cap
Top Inlet Manifold Orifice
Side Inlet Manifold Orifice
Manifold Outlet
Figure 10. Inlet Piping
•
Align Tailpiece and manifold orifi ce.
• Secure to manifold with union nut hand tight only. Do
not overtighten. Do not use pipe joint or thread tape.
• If using the sweep elbow. Use approved NSF
adhesive to glue the sweep elbow onto the cut pipe.
•
Repeat the above steps for the manifold outlet. Again
paying special care to ensure proper seating of the
union tailpiece o-ring.
•
Install the union nut and drain cap with o-ring at the
unused inlet on the heater manifold. Be sure that the
o-ring is properly seated. Secure hand tight only. Do
not overtighten. Do not use pipe joint or thread tape.
•
Return all valves to their operating positions.
•
Restore power to the heater at the breaker.
• Turn on pump and inspect carefully for leaks.
•
Restore main gas supply.
•
Start the system and check for proper fl ow.
•
Return heater to normal operation.
WARNING
To avoid an electrical shock hazard, which can result in serious
injury or death, ensure that all electrical power to the system is
turned off before approaching, inspecting or troubleshooting any
leaking valves or plumbing that may have caused other electrical
devices in the surrounding area to get wet.
Followallfiltermanufacturer’sinstructions.Never
attempt to assemble, dis as sem ble or adjust the
filterwhenthereispressurizedairinthesystem.
Starting the pump while there is any pressurized
airinthesystemcancausethefilterlidtobe
blown off, which can cause death, serious
personal injury or property dam age.
5.3
Water Pressure Switch Adjustment.
The water pressure switch is inside the heater jacket on
the water connection side See
Section
1.8,
item “f”.
The switch is preset at the factory
for activation at 2 psi
(14 kPa). The pressure switch setting must be adjusted If
the heater is installed:
• Below the surface level of the pool
• More than two feet above the pool level
• Where the pressure is measured at 1 psi or greater
with the fi lter pump off
Location of the heater above or below the pool water
surface can also affect the operation of the switch. The
factory installed switch can accommodate elevations of
6 feet above the pool water surface or 11 feet below pool
water surface. If the heater water connections are outside
this range Consult your local Zodiac
®
representative for
recommendations.
•
Set the heater control to ”OFF”.
•
Remove seven screws securing the side panel to the
heater body.
•
Remove the side panel to gain access to the water
pressure switch. See
Figure 11.
•
Turn the fi lter pump on and confi rm that the pressure
switch closes with a voltmeter.
• If the switch does not close, check that all valves are
open to the heater and that there are no restrictions in
the line. You may also need to confi rm fl ow rate from
your pump as outlined in
Section 5.1.
CAUTION
The water pressure switch should be adjusted to turn the
heater off when the pump is off. Setting the switch to close
attoolowflowcandamagetheappliance.Adjusttheswitch
to turn the heater off, not on.
NOTE: It is recommended that a Pressure Release Valve
(PRV) be installed prior to taking any of the steps below.
Please see
Section
5.5
for details.
Pressure
Switch
Rotate clockwise with fingers
until heater turns off. Then rotate
couterclockwise 1/4 turn to set.
Leads
Adjustment
Sprocket
Figure 11. Water Pressure Switch Adjustment