8.2.1
OPERATING INSTRUCTIONS
Refer to the Lighting and Shutdown Instructions. See
Figure 17
located inside the top panel.
•
STOP! Read IMPORTANT SAFETY
INFORMATION in previous section.
• Set temperature thermostat controls to their lowest
setting and turn off the controller. Make sure the
display shows GAS HEATER IS OFF.
• Turn off all electrical power to the heater at the
junction box.
Figure 16. Gas Valve
Gas Valve
Control Switch
ON
• This appliance is
equipped with an ignition
device which automatically
lights the heater. Do NOT
try to light the burner by
hand.
•
Remove the heater rear
or top panel.
• Toggle gas control
switch to OFF position. See
Figure 16
.
•
Wait fi ve (5) minutes to clear out any gas, then smell
for gas, including near the fl oor. IF YOU SMELL
GAS, STOP! Follow instructions in Section
8.1.1.
• If no gas is detected, toggle gas control switch to ON
position.
•
Replace the rear panel or top.
• Turn on electrical power to the heater.
•
Turn the controller ON by pressing POOL or SPA
and set the temperatures as necessary.
• NOTE:
If the heater does not start, check that the
fi lter pump is ON, the fi lter is clean and that water
is fl owing to the pool. If the heater still does not
operate, follow the procedure in Section
8.3
to turn
off gas supply to the heater.
WARNING
Whentheheaterisfiredforthefirsttime,thecombustionchamber
refractorybindermaterialisdrivenoutbytheheatoftheflame.
White smoke and/or sharp odors may be emitted from the vent dur-
ing this period. Do not inhale combustion product fumes at any time,
and especially when these fumes are being emitted. This “burn-in”
period will last only a few minutes.
8.2.2
If Ignition Is Unsuccessful
If ignition is unsuccessful, or the fl ame fails during
normal operation, the ignition control shuts off the gas
valve. The heater will then go through a post purge
process and attempt to establish stable combustion two
additional times. If ignition is unsuccessful after three
attempts, the system shuts down and will automatically
attempt to restart after one hour.
•
To reset the heater to provide three (3) attempts to
start:
• Turn OFF the control then turn it back ON.
•
Access either the Pool or Spa mode.
8.3
To Turn Off Gas To The Heater
• Set temperature thermostat controls to their lowest
setting and turn off the controller. Make sure the
display shows GAS HEATER IS OFF.
• Turn off all electrical power to the heater at the
junction box.
•
Remove the rear panel or top.
• Toggle gas control switch to OFF.
•
Shut off the external gas supply valve to the heater.
•
Replace the rear panel or top.
8.4
Normal Operation
During normal operation, the control system measures
the temperature of the water fl owing through the heater
and will begin the start-up process if the temperature is
below the set point. If the blower pressure switch senses
adequate airfl ow when the blower starts, the ignition
sequence begins. Following a pre purge, the igniter is
energized, then the gas valve opens. As long as a fl ame
is sensed at the burner, operation continues until the
temperature of the water entering the heater reaches the
temperature control setting.