Jandy JXi 200 Installation And Operation Manual - page 4
Page 4
ENGLISH
Jandy
®
Pro Series, JXi
™
Gas-Fired Pool & Spa Heater
|
Installation & Operation Manual
1.5
Specifi cations
SUPPLY GAS
INSTALLATION LOCATION*
NATURAL GAS (NG)
CERTIFIED INDOOR/OUTDOOR
LIQUID PROPANE (LP)
CERTIFIED INDOOR (US ONLY) / OUTDOOR / COVERED SHELTER
GAS PIPE HEATER GAS VALVE
CONNECTION
†
NATURAL GAS (NG)
3/4” NPT
LIQUID PROPANE (LP)
3/4” NPT
INLET GAS SUPPLY PRESSURE
Min
Max
NATURAL GAS (NG)
4.0” WC
14.0” WC
LIQUID PROPANE (LP)
GAS VALVE OFFSET PRESSURE
‡
NATURAL GAS (NG)
.2” WC
.2” WC
LIQUID PROPANE (LP)
WATER PIPE/HEATER CONNECTION
NATURAL GAS (NG)
• PVC/CPVC 2” unthreaded
• Jandy Pro Series threaded union
LIQUID PROPANE (LP)
WATER FLOW RATE
Min
Max
NATURAL GAS (NG)
30 gpm
(76 lpm)
100 gpm
(454 lpm)
LIQUID PROPANE (LP)
WORKING WATER PRESSURE
Min
Max
NATURAL GAS (NG)
2 psi
50 psi
LIQUID PROPANE (LP)
EXHAUST VENT CONNECTION SIZE
(CATEGORY I)
§
NATURAL GAS (NG)
• Model 200: 6
"
• Model 260: 7
"
• Model 400: 8
"
LIQUID PROPANE (LP)
EXHAUST VENT CONNECTION SIZE
(CATEGORY III)
NATURAL GAS (NG)
See Section
3.3.2
LIQUID PROPANE (LP)
ELECTRICAL SUPPLY
NATURAL GAS (NG)
• 120 VAC
• 240 VAC
LIQUID PROPANE (LP)
HIGH ALTITUDE
NATURAL GAS (NG)
Appliances are normally derated when installed at high elevation. This is
not necessary with the JXi heater because it has a special venturi-type
combustion system which self-compensates for changes in barometric
pressure.Airflowthroughtheblowerinletpullsthecorrectflowofgasinto
the burner regardless of air density.
JXiheatersareCSAcertifiedforelevationsofupto4,500feetabovesea
level. At elevations above 4,500 ft., the heater BTU output can be expected
to be reduced by 4% for every 1,000 feet over 4,500 feet above sea level.
LIQUID PROPANE (LP)
* Indoor installation is not recommended for liquid propane heaters.
Review Special Precautions for liquid propane heaters (Section
4.4
)
Anychangestotheheater,gascontrols,airorifice,gasorifices,wiring,or
improper installation may void the warranty. If change is required to any of
the above; contact your local Jandy distributor, visit www.jandy.com or call
technical support at 800.822.7933.
†For gas pipe size requirements see
Section 4
‡ All readings must be taken while the heater is operating
§ Use type B double-wall gas vent, per table 13.1(a) NFPA 54
1.6
Dimensions
Figure 1.
General Dimensions
Dimensions are identical
for all heater models
22.1" (56 cm)
24.9"
(63 cm)
16"
(40.6 cm)
21.6" (55 cm)
5.1"
(13 cm)
5.6"
(14 cm)
10.13”
(26 cm)
18.5”
(47 cm)
5.6"
(14 cm)
10.13"
(26 cm)
Versa Plumb
®
Inlet
18.5"
(47 cm)
35.4" (90 cm)
26.5"
(67 cm)
22.1" (56 cm)
24.9"
(63 cm)
16"
(40.6 cm)
21.6" (55 cm)
35.4" (90 cm)
26.5"
(67 cm)
Inlet