7.3.1
To Restore Heater Control Panel Functionality After Connecting to an External Controller
• Turn power to the heater ON. The heater display
shows:
JANDY REMOTE ONLINE PUSH MENU
TO DISABLE
.
• Press MENU to remove message and restore
functionality to the heater control panel.
7.3.2
To Return Control Back to a Connected External Controller
• Turn power to the heater OFF then back ON.
• Press and hold MENU
for 5 seconds to access Setup
Mode.
• Choose JANDY REMOTE.
Section 8. Operating Instructions
Follow the instructions outlined below to start the heater.
Refer to the Lighting and Shutdown Instructions label on the
inside lid panel of the heater. See
Figure 17
All questions should be directed to technical support at
800.822.7933. Additional information can be found at
www.jandy.com.
WARNING
Ifyoudonotfollowtheinstructionsbelowexactly,afireorexplosion
may result, causing property damage, personal injury or loss of life.
8.1
Important Safety Information
Read Before You Start:
• This appliance does not have a pilot light. It
is equipped with an ignition device, which
automatically lights the heater. Do NOT try to light
the burners by hand.
•
BEFORE OPERATING, smell all around the
appliance for gas. Be sure to smell next to the floor
because some gas is heavier than air and will settle
on the floor.
8.1.1
What To Do If You Smell Gas
• Do not try to light any appliance.
• Do not touch any electric switch; do not use any
phone in your building.
•
Immediately call your gas supplier from a neighbor’s
phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the Fire
Department.
• Use only your hand to switch on or off the gas
control switch. Never use tools. If the switch appears
broken or will not move, don’t try to repair it, call
a qualified service technician. Force or attempted
repair may result in fire or explosion.
• Do not use this appliance if any part has been under
water. Immediately call a qualified service technician
to inspect the appliance and to replace any part of the
control system which has been under water.
8.2
First-Time Start-Up Procedure
WARNING
Vent pipes and heater tops get hot! These surfaces can cause
serious burns. Do not touch these surfaces while the heater is in
operation.
Do not use this heater if any part has been under water. Immediately
callaqualifiedservicetechniciantoinspecttheheaterandreplace
any part of the control system and any gas control which has been
under water.
Should overheating occur or the gas supply fail to shut off, turn off
the manual gas control valve to the heater.
Do not attempt repairs on the gas controls or appliance. Tampering
is dangerous and voids all warranties
•
Confirm that pool water is flowing normally through
the pool system and equipment.
•
If it is a new pool or spa installation, operate the filter
pump with the heater off long enough to completely
clean the water. This will remove any installation
residue from the water.
•
Clean the filter before starting the heater.
• Start the heater in either Pool or Spa mode. See
Figure 17
.
• Start the heater. See
Figure 17.
•
When the heater starts, confirm there is adequate
water flow. See
Section 5
for details.