The Alarm functions operate with the same features that are available on most of the car
alarms available today and include many auxiliary features as well as remote start.
Functions include
Separate Arm and Disarm buttons on the remote that also can lock and unlock the vehicles
doors.
Forced entry detection while armed with separate inputs for doors, hood, trunk/camper shell,
and for sensors such as impact or motion detectors. Note, the sensor inputs can also be config-
ured to have different functions. Please consult with your installer or review the installation
options for details. Typically the alarm trigger will cause the alarm siren to sound and the
horn to honk, but this feature is also programmable.
Remote Start with a 15 minute run time
Auxiliary 1 Can trigger slider doors, windows, etc.
Auxiliary 2 Can trigger slider doors, windows, etc.
Auxiliary 3 Can be used as a door pop output (K9 functions activated), trunk pop output
The Keychain remote
Button #1 is used to turn On the vehicle security system which is connected to all entry doors.
Pressing and holding button 1 for 4 seconds triggers the panic mode and sound the alarm.
Button #2 is used to turn Off the vehicle security system.
Button #3 When button 3 is held for 2 seconds it can to trigger the auxiliary 1 output at the
ECU. This is usually a door pop or trunk pop output.
Button #4 When button 3 is held for 2 seconds it will remotely auto start the vehicle.
Button #5 Shift Key. When button 5 is pressed momentarily it acts as a shift key which can
be used in combination with buttons 1-4 to trigger more functions or to arm/disarm a second
vehicle.
For two vehicle operation the remote must first be programmed to the second vehicle. Once
programmed you can momentarily press button 5 then momentarily press button 1 to arm the
second car alarm. You can likewise momentarily press button 5 then momentarily press but-
ton 2 to disarm the second car alarm.
To trigger auxiliary 1 you can momentarily press button 5 then momentarily press button 3.
To trigger auxiliary 2 you can momentarily press button 5 then momentarily press button 4.
Alarm Functions Described