KEB 00F6P00-1000 Instructions For Use Manual - page 24
5.6.1 Operator system parameters (OS)
Only the meanings of the parameter values are described in the following. Value range, data
length and data type; Access mode and the default values can be taken from COMBIVIS.
OS00
Operator type
Parameter address
0x0180
Value
Meaning
e.g. 12700
Displayofoperatortype(configurationnumber)
• 12710 : F6 Ethernet
• 12700 : F6 default + USB
OS01
Password
Parameter address
0x2181
Value
Meaning
-1…-9
Displays the actual password level of the operator, independent of the inverter. Is used
toentertheoperatorpasswordlevelandisalsotheactualfilelevel:
• 550=userread-only,filelevel=5
• 660=userread/write,filelevel=6
• Supervisor,filelevel=7
OS02
Ftp mode
Parameter address
0x2386
Value
Meaning
0...1
Activation of the FTP mode. The FTP mode can also be started via the main menu.
• 0: Inactive
• 1: Active
OS03
Startup mode
Parameter address
0x2387
Value
Meaning
0…8
The startup mode determines the display during switch on.
• 0: Main menu
• 1: Inverter parameters
• 2: Operator Parameters
• 3: Parameter backup
• 4: Download mode
• 5: Worklist mode
• 6: File administration
• 7: FTP mode
• 8: Test mode
24
OPERATION