KEB COMBIVERT F6 Instructions For Use Manual - 6 Technical Data
6 Technical Data
6.1 Operating conditions
Definition acc.
EN 61800-2
Drive converter-Product standard:
Rated specifications
EN 61800-5-1 Drive converter-Product standard:
General safety
EN 61800-3
Drive converter-Product standard:
eMc
6.1.1 climatic conditions
Operation
Temperature control cabinet EN 60721-3-3 3K3
extended to -5…45 °C (use frost protection for liquid
cooling systems and temperatures below zero)
Humidity
5…85 % (without condensation)
Site altitude
max. 2000 m above sea level (from 1000 m, a derat-
ing of 1% per 100 m take into account)
Transport
Temperature
EN 60721-3-2 2K3
Completely empty the liquid cooling system
Humidity
(without condensation)
Storage
Temperature
EN 60721-3-1 1K4
Completely empty the liquid cooling system
Humidity
1K3
(without condensation)
cAUTION
1) Above 2000 m, there is no "safe isolation" of the control.
6.1.2 Mechanical ambient conditions
Operation
Vibration
EN 60721-3-3 3M1
Transport
Vibration
EN 60721-3-2 2M1
Surge
max. 100 m/s²; 11 ms
Storage
Vibration
EN 60721-3-1 1M1
Surge
max. 100 m/s²; 11 ms
6.1.3 Other operating conditions
Operation
Contamination
Gases
EN 60721-3-3 3C2
Solids
3S2
Transport
Contamination
Gases
EN 60721-3-2 2C2
Solids
2S2
Storage
Contamination
Gases
EN 60721-3-1 1C2
Solids
1S2
Type of protection
EN 60529
IP20
environment
IEC 664-1
Pollution degree 2
60
TecHNIcAL DATA