4.5 DIP-switch settings
Changes in the DIP-switch settings will take effect once the charging station has been restarted!
To do this press the
[Service button]
for
1 second
or switch the power supply voltage off/on.
DIP-switches
DIP-switches
The DIP-switches are used for the addressing
and configuring the charging station and are
located under the connector panel cover.
[DSW1]
…configuration (upper DIP-switch)
[DSW2]
…addressing (lower DIP-switch)
DIP-switch example
The figure shows for a better explanation, the
position of the DIP-switches for the ON and
OFF state.
INPUT/OUTPUT (DSW1) / ONLY FOR STANDARD MODE
Function
DIP-switch
Figure
External enable input [X1]
is used
D1.1
ON=yes
Switch contact output [X2]
is used
D1.2
ON=yes
SmartHome interface via UDP
(details see “UDP Program-
mers Guide”)
D1.3
ON=
enabled