SERIES EN 54-16 certified PA/VA System
Page
10
sur
51
Ϯ͘Ϯ͘ϳ
ZONE SELECTION WINDOW
In the zone selection window, over the
zone/zones to make a selection. If you click on
a selected zone, it will be deselected. When the
zone is selected, the button will show a band.
There may be zones that are not displayed on
the screen, to scroll through the zone selection
window, use the scroll controls, located at the
right side of the screen. On the right side of the
window, the scroll bar indicates the current
position in the window (see 2.2.6).
Once the selection has been made, press
the "OK" control to confirm navigation,
pressing the "BACK" button, the selection will be cleared. If you did not select any zone, and press "OK",
and the equipment / system will perform an automatic selection of all zones.
In each zone depicted on screen, it is indicated the state of the zone. It will be identified as follows:
ĂͿ
ZONE IN STATE OF EMERGENCY
Red box on the left side of the zone button. In Picture 4, zone 1
ďͿ
SELECTED ZONE
Selection band in the right side. In Picture 4, zones 1, 2, 3, 4 and 7
ĐͿ
ZONE INDICATING FAULT
Yellow rectangle on the left side of the zone button. In Picture 4 zone 4
ĚͿ
AREA NOT SELECTED
No selection band. In Picture 4, zones 5 and 6. Zone 8 cannot be selected by default once disarmed.
(see 3.4).
ĞͿ
DISARMED ZONE
Disabled zone. Yellow band on the right side. The button will be a dark-colored area in Picture 4 zone 8
Picture 4: Zone selection window
Page
11
sur
51
Ϯ͘ϯ
USER PROFILES - ACCESS LEVEL. PASSCODE
The access levels define the different user profiles that can operate the equipment / system. Each of
the access levels provides permissions to different menu items, level 1 having the lowest, and level 3 the
highest number of options available.
To access a specific level of access, you must perform access control satisfactorily. Once done, you
can navigate the options, until you return to the home screen, or do not perform any operation for more
than 90 seconds.
The way to perform access control can be set in each of the levels. It is possible to choose from
confirmation mode, or access via 4-digit passcode with the configuration application.
Ϯ͘ϯ͘ϭ
ACCESS LEVEL 1
The access level 1 corresponds to the general user profile, or people who have a general responsibility
for security supervision, which may initially respond to an emergency status, or failure.
Ϯ͘ϯ͘Ϯ
ACCESS LEVEL 2
The access level 2 corresponds to a security manager profile who has specific training to operate the
equipment / system in the states of "PA", "Emergency", "Failure message" and "Disarmed".
Ϯ͘ϯ͘ϯ
ACCESS LEVEL 3
The access level 3 corresponds to the administrator profile, who has specific training to modify the
system configuration and perform the maintenance, according to the instructions and information
presented in this manual.
Ϯ͘ϰ
INPUTS Y OUTPUTS
In this chapter are described the rear connectors of the EXEO series equipment. Depending on the
model, the equipment will or will not include some of the types described in this section and quantity
may vary.
Picture 5: Types of Control Access Windows
Picture 6: Inputs and Outputs