PROBLEM
ACTION TO TAKE
Auger Is not Turning
Fan Does Not Run
For any additional operation issues not covered in this guide,
please contact your local MAK GRILLS DEALER. You may also
phone us at (503) 623-1234 between 9AM-4:30 PM, Monday-Friday,
Pacific Time. You may also contact us via email:
service@makgrills.com
?
?
?
If the pellets have jammed your auger,
you will need to remove the auger and
clean out the auger and auger tube.
This can be done by removing pellets out
of the hopper and removing the firepot.
Use a shop-vac to suck out as many of
the pellets from each end of the auger
tube. Remove the back panel, fan, and
fan deflector. Unplug the auger from the
circuit board. It is labeled AUGER.
Loosen the auger set-screw from the
access hole underneath the motor and
pull the auger out through the back of the
unit. Clean out any remaining wet pellets
or dust from the auger, auger tube and
surrounding areas. Replace auger in
reverse order and test to see if auger
turns before adding new pellets.
Never put spilled pellets from the
ground back into your pellet hopper.
?
?
Check the fuse located on the front of the
control board to make sure it has not
blown.
The fan should run any time the power is
turned on. If the fan is not turning,
disconnect the power, remove the
and make sure the fan plug is
securely plugged into the back of the
board. The plug is labeled FAN.