NAPCO Gemini GEM-P816 Programming Instructions Manual - page 18
X
GEM-P816 Programming Instructions
L
NAPCO Security Systems
!
Page 18
WI995C 2/04
SYSTEM OPTIONS (ADDRESS 0718-0722, 1060-1062)
*NOTE: Address 0721:
Default depends on Easy Menu Question :“
EZ
ZONE DOUBLING? Y/N
”. If yes, then [Default = 1]. If no, then [Default =
blank (•)].
**NOTE:
To select “Line-Fault Test only when Armed”, you must also se-
lect “Enable Line-Fault Test” at address 0721.
*** NOTE:
If “Enable Global Ambush Code” in Address 0720 is selected, then
program the 2-digit “Global Ambush Code” in Address 1054. If Address
1054 is left blank (•), then, the 2-digit “Global Ambush Code” will be “99”.
0718 System Options
0719
Default
Option
Default
Option
OFF
1
Opening Report Only after Alarm Report
OFF
1
Auto Bell Test on Arming
OFF
2
Closing Report Only on Conditional Close
OFF
2
Auto Reset after Burglary Output Timeout
OFF
3
Incl. Sel./Grp. Bypass in Cond. Close /Status
OFF
3
Suppress Bypass Reminder when Armed
OFF
4
Status Report
OFF
4
Enable Local Alarm on First Zone AND Trip
OFF
5
Reserved
OFF
5
Access Control on PGM2 Output
OFF
6
Enable AutoArm if not closed at end of Window OFF
6
Maintained Keyswitch Arming
OFF
7
Enable Time/Date KP Display
OFF
7
Enable Manager's Mode
OFF
8
Disable Zone Fault Scrolling
OFF
8
Disable Keypad Instant Mode
System Options
0720 System Options
0721 System Options
Default
Option
Default*
Option
OFF
1
Interior Normally Bypassed
OFF*
1
Enable Zone Doubling (Zones 9-16)
OFF
2
Enable Global Ambush Code ***
OFF*
2
Wireless Trouble Activates Telco 1
OFF
3
Reset Day Zone with Arm/Disarm Only
OFF*
3
Wireless Trouble Activates Telco 3
OFF
4
Enable Residential Fire
OFF*
4
Enable Alarm Output on Telco Fail only when Armed
OFF
5
Disable Keypad Function Mode Download
OFF*
5
Line-Fault Test only when Armed**
OFF
6
Disable Callback Download
OFF*
6
Enable Line-Fault Test**
OFF
7
Chirp Output on Keyfob Arm/Disarm
OFF*
7
Inhibit System Trouble Audible at Keypad
†
OFF
8
Change Pulse Output to Temporal Output
§
OFF*
8
Select Alarm Output for Keyfob Chirp
† NOTE:
Not for UL Installations.
§
This feature must be programmed in Fire Alarm applications.
1060
Default
Option
OFF
1
Enable Keypad Set Time/Date Message
OFF
2
Enable Cancel Report to Telco 3
OFF
3
Disable [ON/OFF] as Easy Exit
OFF
4
Enable GEM-PRINT Module
OFF
5
RESERVED
OFF
6
RESERVED
OFF
7
Disable System Trouble Audible Timeout
OFF
8
RESERVED
System Options
0722
Default
Option
OFF
1
Automatic Interior Bypass/Easy Exit
OFF
2
Veri-phone Zones Trip PGM2 Output
OFF
3
Veri-phone Audio Priority Over Alarms
OFF
4
Resound on Wireless Smoke Low Battery
OFF
5
Don't Clear PGM2 Output with Disarm
OFF
6
Disable 2nd Call Ans. Machine Override
OFF
7
RESERVED
OFF
8
RESERVED
System Options
ADDRESS 1061: LUG E15 OUTPUT MODE
Select the options available from the table above.
!
1. Enter digit only.
!
2. Valid entries are “blank (•)” or “4”. Press
U
or
D
to save.
1061
Lug E15 Output Mode
DATA ENTRIES
OPTION
blank (•)
Armed
4
Armed Area 1 Away
Di
rec
t
A
d
dre
ss
P
rogr
am Mode
1062
Default
Option
OFF
1
Exit Time Restart
OFF
2
Sound Alarm On Exit Error
OFF
3
Rpt Exit Err/Recent Close
OFF
4
Enable CP-01 Limits
OFF
5
Digital Dialer Rpt Enter /Exit Test Mode
OFF
6
Disable Call Waiting on 1st Attempt
OFF
7
RESERVED
OFF
8
RESERVED
System Options