Navien CH-180 Service manual - page 119
©Navien America Inc. 2010
CH series service Manual
117
Version 1.0
7.2. Cleaning the Intake Air Filter
Clean the intake air filter just above the fan and under the air intake pipe in the top
left corner of the boiler as the following.
1. Remove the screw is located in the circled areas in the figure.
2. Remove the intake air filter from the bottom of the intake pipe by pulling it out
towards the front.
3. Remove the filter from the plastic assembly.
4. Clean it with a toothbrush and water.
5. Re-fit the screen in to the plastic assembly and fit the filter.
6. Frame onto the bottom of the air intake pipe.
7. Once the filter is back on the intake pipe, reset the fan back to its original posi
tion.
Insert the fan on an angle into the back corner of the case and then move it into
its correct position,
8. Replace the screws.