Navien CH-180 Service manual - page 60
58
Valve closed
Defective
heat-ing
outlet tem-
perature
sensor
Capacity
setting
Defective
PCB
Thudding
noise
caused by
minimum
flow
Other
trouble
Check heating inlet/outlet valve and distributor room valve.
At least one valve of the distributor must be always open.)
Sudden increase of temperature due to PCB DIP S/W model
setting error or max setting.
If the trouble continues despite the checking of above items,
replace the PCB.
The system recognizes the heating water temperature higher than
it actually is due to a defective sensor.
Check the heating outlet temperature displayed ( ).
Check if there is a significant difference between the tempera
ture displayed and the one actually sensed.
Remove the heating outlet temperature sensor connector only,
connect a good temperature sensor, and determine if the
temperature sensor is defective. Refer to the resistance
measuring criteria and the method of measurement.
exchanger is clogged> G ©Navien America Inc. 2010 CH series service Manual Version 1.0