65
No spark from
electrode
Main gas
valve
Ignition
failure
When no spark is made from the electrode at ignition:
Remove the electrode and check if there is a crack on the
insulator.
Adjust the gap if there is a discharge of electricity from the
metallic part of the combustion room.
Add the insulating packing to the insulator of the electrode.
Check the input power to the ignition transformer (AC 120V).
If there is no trouble in the input power to the ignition trans
former, replace the ignition transformer.
Replace the PCB if there is a trouble in the power supply to the
ig-nition transformer.
Check the insulator boots on spark wires for cracks/holes.
1. Check the primary/secondary power supply to the main gas
control valve.
Check, with a tester, if the input power is DC 100V.
2. Replace the PCB if power is not supplied.
3. If power supply is normal, check if the coil is open.
4. Check if the solenoid valve works properly.
Feel or hear a click.