6.2. FoundaTion / accessories
When installing a charging pillar, please ensure that the foundation has been
appropriately dimensioned. The regional conditions (soil quality, ground water
level, etc.) are to be considered here.
recommendaTion For The dimensioning oF a FoundaTion:
In the following you can see example data for the construction of a foundation
as recommended by the manufacturer!
The following cast-in-place foundation is not a base for the foundation mount-
ing frame but should be seen as an alternative to the foundation mounting
frame.
As an option the P-CHARGE foundation mounting frame can be integrated into
a cast-in-place foundation. We supply the following accessories to assist you in
this procedure:
suBsTrucTure mounTing Frame:
Use of foundation mounting frames makes construction of a foundation easier
as all nuts required for securing the pillar or running cables are already in
place. The mounting frame is set in concrete. Delivery includes 4 x M12 screws
and washers. The respective cover plates must be removed in order to install
cable conduits.
When constructing the foundation, please ensure that the upper edge of the
mounting frame protrudes approx. 10-15mm above ground level to avoid
problems when opening the charging station door.
connecTion seal:
We can supply a base plate seal as optional protection against corrosion to the
interior of the charging pillar. The seal is fitted between the base plate of the
pillar and the foundation. Depending on the diameter of the electrical supply
cable, the cable grommets are opened with a knife
carporT console:
The carport console is compatible with carports of design B2 and B3 which are
constructed using a micro-pile foundation. The cannot be used in conjunction
with the B1 carport due to an incompatible design of the carport.
6.3. environmenTal condiTions
The charging station is designed for installation and for orderly use in public
areas. It is designed for outdoor installation in accordance with the following
criteria:
Type of protection
0-95%
Temperature range:
0-95%
Humidity:
0-95%
Front view
Top view
Side view
Picture 6: Detail view founda-
tion recommendation
Picture 7: Substructure mounting frames
Picture 8: Connection seal: