6.4. service noTes
The charging pillar is designed to require minimal maintenance. It can be
cleaned with common detergents as necessary. Please avoid the use of scrub-
bing powders or detergents with abrasive particles.
The P-CHARGE is equipped with calibrated meters. These have a validity of 8
years and are approved for use by third parties for the calculation of energy.
Once this time has elapsed, either a new meter is to be installed, or the existing
device must be audited by the calibration office. The device must be calibrated
regularly to ensure a consistently accurate billing process.
We recommend a complete functionality audit of the P-CHARGE Stand-Alone
every 6 months to ensure the best possible performance of the device. Test the
different functions using the menu item "Tests" and perform a measurement at
all the socket outlets according to VDE0100. In the event of outage, operation
may be re-started only by qualified a technical electrician (according to BGV
A3, DIN VDE 0105-100 and DIN VDE 1000-10 or according to the valid national
regulations)
6.5. error messages / proBlems
•
POWER FAILURE: In the event of power failure, the charging station will
automatically shut down. Once power is reestablished, the charging sta-
tion will restart by restoring the status saved at the point of outage.
•
RCD trip: In the event that the fault current protection switches are
tripped, these must be reset manually by a service technician.
•
Loss of RFID card: Anyone finding a lost RFID card has authorization to
use it at the corresponding charging pillar. Users should therefore be
warned in advance to take good care of their card. A lost RFID card can
be blocked via the EWS Box website. Instructions to this end can be
found in Section 7.
•
Outlet "xy" cannot be selected / displays WP or WS: Should an unused
outlet not be available for selection, then "WP" or "WS" is shown on the
display behind the respective outlet. This problem occurs if the plug is
removed without deactivating the outlet; the socket is reactivated for
further use after 5 mins.
•
In the event of other errors: First, restart the charging station. The control
fuse "F0" and all RCCBs "F1, F2, F3, F4" are hereby deactivated and, after
approx. 30 seconds reactivated. Should the fault remain, the next step is
to check the settings in the Customer Menu, as outlined in section 5.2.
Correct these if necessary. Restart the system once changes have been
saved. Should the fault still remain, please contact the service partner.
please noTe
The exact position of the plug connections on the EWS Box can
be referenced in the EWS-box Quick guide to operations / HTML configuration.
This can be found via the link in Section 7 / EWS Box Quick guide to
operations / HTML configuration on the SSL Energie GmbH homepage.