Pacific Energy NEO 1.6 Installation And Operating Instructions Manual - page 13
220114-20
NEO 1.6 INSERT-A
13
4) Push the Insert into position inside the fi replace and at-
tach the fl ue collar to the opening in the top of the insert
fi rebox. Use the rear adjusting legs to level the Insert.
5) Measure, trim and shape a top fl ashing to fi t the existing
chimney fl ue. Plan for a 1” to 1-1/2” overlap on each side.
Place fl ashing over top of the liner and seat fi rmly against
the tile.
6) Screw fl ashing collar to liner. Caulk gap around fl ashing
with RTV silicone.
7) Attach a rain cap to the end of the liner. A storm collar
may be used if desired.
Direct Flue Connection - (USA only)
1) Measure from the fi rst chimney fl ue liner to the top of the
Insert. Allow extra length of liner to insert into fl ue tile.
2) Feed the stainless steel liner through the damper area
and into the fi rst chimney fl ue tile. Seal around pipe to
the chimney.
Note: A clean-out door may be required under local codes,
when a direct fl ue connection is used. Consult local codes.
Note: It is necessary to get access to the removable collar
through the fl ue outlet of the Insert, the baffle should be re-
moved (see Baffle Removal section page 8).
3) Attach the removable fl ue collar to the end of the chimney
liner with three stainless steel screws. Push the Insert into
position inside the fi replace.
4) Reach up through the fl ue opening in the fi rebox and pull
the removable fl ue collar down with the tool provided and
center on the hole.
5) While holding in place attach the clamps and tighten fi nger
tight to hold the collar in place. Tigthen securely with a 1/2”
wrench or socket. Use the rear adjusting legs to level the
insert.
Chimney
Flue Liner
6" Stainless Steel
Rigid or Flex Liner
Mantel or
Top Facing
Direct Flue Connection
Fig. #6
Into a Factory Built Fireplace
Your Insert may be installed into a factory built fi replace (size
permitting) with the following requirements:
1) Inspect your fi replace for damage or other physical defects.
The fi replace must be in good working condition. If in doubt
about its condition, seek professional advice. Check for
creosote build up or other obstructions inside the chimney,
especially if it has not been in use for some time. Before
installing, clean your chimney system thoroughly.
2) A full stainless steel rigid or fl exible fl ue liner meeting type
HT requirements (2100°F) per 1777 (U.S.) or ULC S635
(Canada) must be used for both safety and performance.
The liner must be securely attached to the Insert fl ue collar
and the chimney top.
3) The surround must be sealed to the fi replace front or the
damper area around the chimney liner must be sealed to
prevent room air entering the chimney cavity of the fi replace.
4) The air fl ow within and around the fi replace must not be
altered by the installation of the Insert (i.e. no blockage of
louvers or cooling air inlet or outlet ports). This includes
the circulating air chambers in a steel fi replace or metal
heat circulator.
5) Alteration of the fi replace in any manner is not permitted
with the following exceptions:
a: external trim pieces which do not affect the operation
of the fi replace may be removed and stored on or within
the fi replace for re-assembly if the Insert is removed.
b: the chimney damper may be removed to install the liner.