Offsets
15'
30° or 45°
ELBOWS
around the fi replace.
The chimney for the FP30 can be installed with a maximum
of four 45° elbows(in Canada) and four 30° elbows(in
U.S.A.) as shown in Fig. #12.
Installation:
1. Install the fi rst elbow; turn it in the required direction. It
is required to secure connections with three (3) #8 x ½"
(12 mm) metal screws.
2. Install the necessary chimney lengths to achieve the
required offset. Lock the chimney lengths together ac-
cording to the chimney manufacturer’s instructions. It is
required to use three (3) #8 x ½" (12 mm) metal screws
at every connection of the chimney. If the offset length is
made of two (2) chimney lengths or more, many chimney
manufacturers require that you use an offset or roof sup-
port halfway up the offset. If penetrating a wall, install a
wall radiation shield supplied by the chimney manufacturer
and install according to the manufacturers installation
instructions.
3. Use another elbow to turn the chimney vertically, Secure
the elbow.
4. Use a plumb bob to line up the centre of the hole. Cut a
hole for the chimney in the ceiling/fl oor. Frame the hole as
described on page 16 and as per chimney manufacturer's
instructions.
5. From below, install a fi restop supplied by the chimney
manufacturer.
FIG. #12
7’ (2.13m)
15’ (4.57m)
25’ (7.62m)
18” (457mm)
Minimum width of floor protection from side of door opening(in U.S.A.) and
from side of unit(in Canada).
Fireplace Clearances and Dimensions
30” (737mm)
35’ (10.7m)
Recommended maximum chimney height (at sea level) from top of fireplace
to rain cap.
Minimum distance of adjacent wall to side of fireplace door.
Distance of combustible material from side, back standoffs and framing kit.
Ceiling clearance: from the base of the fireplace to the
ceiling.
Minimum chimney height: minimum total chimney height from fireplace top to
below the chimney rain cap.
Maximum chimney height supported by fireplace.
Minimum depth of non-combustible hearth extension: from the front of the
fireplace.