Pacific Energy PACIFIC FP30 Installation and operating instructions manual - page 21
PACIFIC FP30 060514-28
21
70” min
1.78m
12” min
305mm
FLOOR
CEILING
11 1/4”
286mm
9 3/4”
248mm
FIG. #20
FIG. #21
3. Locate and cut a 11 1/4”(286mm) X 9 3/4”(248mm) open-
ing in the wall or facing material being sure to maintain
structural integrity.
4. The centerline of the outlet must be a minimum 70”(1.78m)
off the fl oor, 16"(406mm) from any adjacent wall and a
minimum 12”(305mm) from the ceiling.
5. Bend the securing tabs on the outlet adapter inwards and
insert the 6"(150mm) fl exible Type "B" venting provided
approximately 1/2”(13mm) into the opening in the wall
outlet. Secure to the outlet with two #8 X 1/2"(13mm) Tek
screws from the outside.
6. Insert the vent pipe through the opening in the wall and
position the pre-assembled wall outlet in the hole being
careful not to damage the insulation. Cover outlet adapter
with outlet screen provided or one of equal outlet area.
7. A maximum 20'(6.1m) total run including 2 - 90° bends
are allowed. The venting should only run horizontally or
up, never in a downward direction.
8. Maintain clearances to combustibles as described in the
venting manufacturer's specifi cations and use a fi restop
if passing through a fl oor or wall.
9. Connect the vent pipe to the heat duct adapter on the top
of the unit and secure with three #8 X 1/2’(13mm) Tek
screws.
NOTE: FOR A SINGLE GRAVITY VENT AND WHEN THE
FACING MATERIAL IS LESS THEN 3/4"THICK, THE UNIT
WILL DRAW SUFFICIENT AIR THROUGH THE OPENING
BENEATH THE ASHLIP.
10. If running two gravity vents and/or if your facing material
is more than 3/4”(19mm) thick(Max. 4"(102mm)), connect
an additional room air inlet to the 6"(150mm) Gravity Vent
inlet adapter on the left side of the fi replace casing(Fig.
#22).
FIG. #22
SECURING
TABS
WALL
OUTLET
GRAVITY HEAT DUCT AIR INLET. used only when
two gravity vents and/or your facing material is more than
3/4”(19mm) thick(Max. 4"(102mm)), NOT RELATED TO
CHASE AIR INLET