Qcom LR802UKN3 User Manual - Test Report
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested. This test report cannot be reproduced, except in full, without prior written permission of
the Company. 除非另有說明,此報告結果僅對測試之樣品負責。本報告未經本公司書面許可,不可部份複製。
This Test Report is issued by the Company under its General Conditions of Service printed overleaf or available on request and accessible at
http://www.sgs.com/terms_and_conditions.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this Test Report is
advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole
responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. Any
unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
No. 33 Wu Chyuan Road, Wuku Industrial Zone, Taipei County, Taiwan / 台北縣五股工業區五權路 33 號
t (886-2) 2299-3939
f (886-2) 2299 -3237
www.tw.sgs.com
SGS Taiwan Ltd.
台灣檢驗科技股份有限公司
Member of the SGS Group
Test Result(s)
PART NAME NO.1
:
PART NAME NO.2
:
No.1
No.2
Cadmium (Cd)
mg/kg
With reference to IEC 62321/2nd CDV
(111/95/CDV). Determination of
Cadmium by ICP-AES.
2
---
n.d.
Lead (Pb)
mg/kg
With reference to IEC 62321/2nd CDV
(111/95/CDV). Determination of Lead by
ICP-AES.
2
---
n.d.
Mercury (Hg)
mg/kg
With reference to IEC 62321/2nd CDV
(111/95/CDV). Determination of Mercury
by ICP-AES.
2
n.d.
---
Hexavalent Chromium Cr(VI) by
alkaline extraction
mg/kg
With reference to IEC 62321/2nd CDV
(111/95/CDV). Determination of
Hexavalent Chromium for non-metallic
samples by UV/Vis Spectrometry.
2
n.d.
---
Beryllium oxide (BeO)
mg/kg
With reference to US EPA Method
3050B for Beryllium Content. Analysis
was performed by ICP-AES.
(See Note 10 and Note 11)
5.6
n.d.
---
Antimony trioxide (Sb
2
O
3
)
mg/kg
With reference to US EPA Method
3050B for Antimony Content. Analysis
was performed by ICP-AES.
(See Note 12)
2.4
n.d.
---
Polychlorinated Biphenyls (PCBs)
(CAS No.: 001336-36-3)
mg/kg
With reference to US EPA 3540C
method. Analysis was performed by
GC/MS.
0.5
n.d.
---
Polychlorinated Terphenyls
(PCTs)
mg/kg
With reference to US EPA 3540C
method. Analysis was performed by
GC/MS.
0.5
n.d.
---
Chlorinated Paraffin (C10~C13)
(CAS No.: 010871-26-2)
%
With reference to US EPA 3540C
method. Analysis was performed by
GC/MS.
0.01
n.d.
---
Polychlorinated Naphthalene
(PCNs)
mg/kg
With reference to US EPA 3540C
method. Analysis was performed by
GC/MS.
5
n.d.
---
TBBP-A-bis (CAS No.: 21850-44-
2)
mg/kg
With reference to US EPA 3540C
method. Analysis was performed by
HPLC/DAD/MS.
5
n.d.
---
MDL
MLCC PRODUCTS (CE/2008/67047)
566-1, KAO-SHI ROAD, YANG-MEI, TAO YUAN, 32642 TAIWAN, R. O. C.
Test Item (s):
Unit
Method
Test Report
No. : CE/2008/67047B
Date : 2008/07/07
Page : 2 of 20
WALSIN TECHNOLOGY CORPORATION
*CE/2008/67047B*
Result
MULTILAYER CERAMIC CAPACITORS (CE/2008/65696)