Qcom LR802UKN3 User Manual - Test Report
SGS Taiwan Ltd.
台灣檢驗科技股份有限公司 Chemical-Taipei 33 WuChyuan Road, Wuku Industrial Zone, Taipei County, Taiwan /台北縣五股工業區五權路33號
t + 886 (02)2299 3279
f + 886 (02)2299 3237 www.sgs.com
Member of the SGS Group (SGS SA)
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested. This test report cannot be reproduced, except in full, without prior written permission of the Company.
除非另有說明,此報告結果僅對測試之樣品負責。本報告未經本公司書面許可,不可部分複製。
This Test Report is issued by the Company under its General Conditions of Service printed overleaf or available on request and accessible at http://www.sgs.com/terms_and_conditions.htm. Attention
is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this Test Report is advised that information contained hereon reflects the Company’s findings
at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction
from exercising all their rights and obligations under the transaction documents. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and
offenders may be prosecuted to the fullest extent of the law.
Sample Description
:
Style/Item No.
:
Sample Receiving Date
:
Testing Period
:
============================================================================================
Test Requested
:
Test Method
:
(1)
(2)
(3)
(4)
(5)
Test Result(s)
:
Conclusion
:
2008/09/24 TO 2008/10/01
In accordance with the RoHS Directive 2002/95/EC, and its amendment
directives.
With reference to IEC 62321/2nd CDV (111/95/CDV)
Procedures for the Determination of Levels of Regulated Substances in
Electrotechnical Products.
Determination of Cadmium by ICP-AES.
Please refer to next page(s).
Based on the performed tests on submitted samples, the test results are
compliant with the limits of RoHS Directive 2002/95/EC and its subsequent
amendments.
Test Report
2008/09/24
*CE/2008/96011*
No. : CE/2008/96011
Date : 2008/10/01
Page : 1 of 6
TAIWAN HI-TECH CORPORATION
NO. 17, INNOVATION ROAD 1, HSIN CHU SCIENCEBASED INDUSTRIAL
PARK, HSIN CHU TAIWAN
PURE Tin PLATING(NO. 11)
QFP128
Determination of Lead by ICP-AES.
Determination of Mercury by ICP-AES.
Determination of Hexavalent Chromium for metallic samples by Spot
test / boiling water extraction Method.
Determination of PBB and PBDE by GC/MS.
The following sample(s) was/were submitted and identified by/on behalf of the client as :