Qcom LR802UKN3 User Manual - page 94
NUMBER : THJ0067375
TEST CONDUCTED
PAGE 6 OF 7
Intertek Testing Services Taiwan Ltd.
8/F., No. 423, Ruiguang Road, Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114
台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888 2797-8885 Fax: (+886-2) 6602-2410
(
Ⅱ
) TEST METHOD :
TESTING ITEM TESTING
METHOD REPORTING
LIMIT
1,1,1-TRICHLOROETHANE
1,1,1-
三氯乙烷
WITH REFERENCE TO USEPA 5021 /
8260B AND DETERMINED BY GC-MSD
LINKED WITH HEADSPACE
1 ppm
CARBON TETRACHLORIDE
四氯化碳
WITH REFERENCE TO USEPA 5021 /
8260B AND DETERMINED BY GC-MSD
LINKED WITH HEADSPACE
1 ppm
PHTHALATES
鄰苯二甲酸
WITH REFERENCE TO ASTM D3421-75,
BY SOLVENT EXTRACTION AND
DETERMINED BY GC-MSD
10 ppm
MIREX (PERCHLORDECONE)
滅蟻靈
WITH REFERENCE TO USEPA 3540C, BY
SOLVENT EXTRACTION AND DETERMINED
BY GC-ECD OR GC-MSD
10 ppm
TETRABROMOBISPHENOL-A-bis
(2,3-DIBROMOPROPYLETHER)
(TBBP-A-bis)
四溴雙酚-A-雙(2,3-二溴丙醚)
WITH REFERENCE TO USEPA 3540C, BY
SOLVENT EXTRACTION AND DETERMINED
BY HPLC-DAD OR GC-MSD
20 ppm
HALOGEN (F, Cl, Br, I)
CONTENT
鹵素(氟、氯、溴、碘)含量
WITH REFERENCE TO EN 50267-2-
2:1999 BY TUBE FURNACE COMBUSTION
AND prEN 14582 DETERMINED BY ION
CHROMATOGRAPHY
30 ppm
REMARK : REPORTING LIMIT = QUANTITATION LIMIT OF ANALYTE IN SAMPLE
(
Ⅲ
) MEASUREMENT FLOWCHART:
TEST FOR Cd/Pb CONTENT
******************************************************************************
END OF REPORT
WEIGHED SAMPLE
WAS PUT INTO A
MICROWAVE
DIGESTION VESSEL
CONCENTRATED
NITRIC ACID WAS
ADDED
SAMPLE WAS
DIGESTED IN
MICROWAVE
DIGESTION OVEN
THE DIGESTED
SOLUTION WAS
TRANSFERRED INTO A
VOLUMETRIC FLASK
MAKE UP WITH
DEIONIZED WATER
ANALYZE BY ICP-OES