Page 10
8.
Place the Removable Front Panel back onto the front of the Quik n’ Crispy.
It will slide down at an angle onto the four pins that are located on the
front of the unit.
9.
Please note that on the INTERNATIONAL UNITS ONLY, there is a safety
switch installed on the right rear wall of the cooking chamber. This switch
will be depressed when the Separation Wall is properly installed. If the
Separation is not properly installed, the safety switch will remain in the
Open Position, and the cooking blower will not operate. Insure that when
the Separation Wall is installed that the flat part is making solid contact
with the rear wall of the oven chamber and depressing the safety switch.