Quincy Compressor QED 1050 Instruction And Maintenance Manual - Technical Data
8
Technical data
8.1
Reference conditions and limitations
Reference conditions
Unit
Value
Compressed air inlet pressure
psig
101.53
Compressed air inlet pressure
bar(e)
7
Compressed air inlet temperature
˚F
133
Compressed air inlet temperature
˚C
56
Ambient temperature
˚F
115
Ambient temperature
˚C
46
Inlet relative vapour pressure
1
Cooling air inlet temperature
°F
77/100.4
Cooling air inlet temperature
°C
25/38
Limits
Unit
Maximum compressed air inlet pressure
psig
203.05
Maximum compressed air inlet pressure
bar(e)
14
Minimum-maximum ambient air temperature
˚F
32-115
Minimum-maximum ambient air temperature
˚C
0-46
Maximum compressed air inlet temperature
˚F
122
Maximum compressed air inlet temperature
˚C
56
8.2
Air dryer data
General
Unit
Pressure drop over dryer under nominal conditions, approx.
- QED 650
psi
3.34
- QED 650
bar
0.23
- QED 850
psi
3.05
- QED 850
bar
0.21
- QED 1050
psi
2.9
- QED 1050
bar
0.2
Refrigerant
Instruction book
92