Quincy Compressor QED 1050 Instruction And Maintenance Manual - page 95
QED 850
Performance data
Unit
At ambient
temperature of:
°F
100
77
86
95
104
115
At ambient
temperature of:
°C
38
25
30
35
40
46
Volume flow at dryer
inlet under nominal
conditions
cfm
869
869
869
869
869
869
Volume flow at dryer
inlet under nominal
conditions
l/s
410
410
410
410
410
410
Pressure dew-point
˚F
39
37
39
39
52
72
Pressure dew-point
˚C
4
3
4
4
11
22
Total power
consumption
hp
8.2
8.2
8.2
8.2
9.0
10.3
Total power
consumption
kW
6.1
6.1
6.1
6.1
6.7
7.7
Power consumption,
cooling fan
hp
1.5
1.5
1.5
1.5
1.5
1.5
Power consumption,
cooling fan
kW
1.1
1.1
1.1
1.1
1.1
1.1
Cooling air flow
(approx.)
cfm
5300
5300
5300
5300
5300
5300
Cooling air flow
(approx.)
l/s
2500
2500
2500
2500
2500
2500
Heat dissipated by
cooling air flow
(approx.)
Btu/hr
51200
47800
54600
61400
68200
78500
Heat dissipated by
cooling air flow
(approx.)
kW
15
14
16
18
20
23
QED 1050
Performance data
Unit
At ambient
temperature of:
°F
100
77
86
95
104
115
At ambient
temperature of:
°C
38
25
30
35
40
46
Volume flow at dryer
inlet under nominal
conditions
cfm
1080
1080
1080
1080
1080
1080
Instruction book