Racers Edge SureCharge 2000 LiPo Operating Manual - page 12
VOLTAGE BALANCING AND MONITORING IN THE DISCHARGE PROCESS
The processor monitors the voltage of each cell when the battery packs during “storage” and
-discharging” process. To achieve this feature, plug each battery to the charger individually. If
voltage of any cell is abnormal, the SC2000 will show an error message and terminate the
program forcibly. So if there is battery damage or disconnection, you can see the error message
and press INC to know which cell is damaged.
The processor detects voltage of one cell is too low. The 4th cell
was damaged.
The value of voltage may be zero if disconnection occurs.
Charging NiMH/NiCd Batteries
This program is for charging and discharging of NiCd/NiMH
batteries associated with R/C models applications. You can press
START/ENTER key to make it blink and then INC or DEC to change
the parameter value. Press START/ENTER key to store the value.
This program charges the battery using the current you set up. In the
“auto” state. You should set up the upper limit of the charge current
to avoid damage by excessive feeding current. Some batteries of low
resistance and capacity can lead to higher current in the “auto”
charging mode. But in the manual mode, it will charge with the
current you set. You can make it blink in the current field and press
INC and DEC at the same time to switch mode.
DISCHARGING NIMH/NICD BATTERIES
The screen shows the real-time status. Press BATT TYPE/STOP
key to end the program. The sound will emitted to indicates the end
of program.
Set charge current on the left and the final voltage on the right.
Range of the charge current is 0.1-1.0A; range of final voltage is
0.1-25.0V. Press the Start/Enter key for more than 3 seconds to
start the program.
The screen indicates the discharging state. You can press START/
ENTER key to alter discharge current. Press START/ENTER again
to store the value. Press BATT TYPE/STOP key to stop
discharging. The emitted sound alerts the end of discharging
23
22