RAMSET RL510 Instruction Manual - How to Use The Rl510 Laser
How to Use the RL510 Laser
12
Wait until self-leveled: While the laser is moving on the mount, it does
not self-level and the beam continues to rotate. After moving the laser,
wait a few seconds in case it needs to self-level. Check that it’s still on
the point or level desired, and make adjustments if needed.
Automatic exit from mode: If you have not activated the wall mount
for five minutes, the laser will automatically exit from wall mount
mode and return to the previous mode (3 LEDs will be off and a
beep will sound).
Functions not available: Tilt (H.I. Alert) mode, setting slope in manual
mode, or moving the scan or plumb point are not available in wall
mount mode. Exit wall mount mode to use these functions.
Detaching the mount: Screw both knobs (1) all the way out to detach
the mount from the laser.
Troubleshooting: If the laser does not move on the mount, check that
the knobs (1) are tight enough to make power contact for the motor.
The mount can also be detached to check that the contacts where the
laser and mount are fastened are clean.
2.8.2 Using the Laser Wall Mount on a Ceiling Grid
Setup:
1.
Check that the laser and mount are connected securely. The knobs
(1) should be turned fairly tight to make contact for the motor,
although do not overtighten.
2.
Flip down the support plate (8).
3.
Release the clamp (2) on top of the adjustable plate (3).
4.
Lock the clamp against the ceiling grid. The grid should not exceed
1/8” (3 mm) in thickness.
5.
If the foot on the support plate is not touching the wall, use the
screw (9) to adjust.
To move the laser up or down with the remote control:
1.
Turn on the laser and wait for it to self-level. The head must be
rotating before you can enter wall mount mode.
2.
Press the scanning key (4) on the remote control and hold it for
several seconds until the 3 LEDs blink on the RL510 keypad.
RL510-Manual 3/13/08 3:02 PM Page 12