RAMSET RL510 Instruction Manual - page 21
Check and Calibrate Your RL150
19
If the X LED is blinking and the beam is rotating, it is not in calibration
mode. Turn off and repeat the steps 1-3 again.
4.
If you have not moved the laser, use the X marks made in previous
steps of “Checking X axis”. If you need a rotating beam for the
detector, press the scan key.
5.
Use the arrow keys to move the beam up or down to the halfway
mark. If the X axis is toward the wall with the marks, use key (13) on
the laser keypad or key (6) on the remote control to raise the beam;
use key (14) on the laser keypad or key (5) on the remote control to
lower the beam. (If X’ faces the wall, the movement is the opposite).
6.
After completing the X calibration, press key (16) on the laser
keypad or key (3) on the remote control to change the axis and to
calibrate the Y axis. When the LED blinks slowly, the laser is ready to
be calibrated on the Y axis.
7.
If the Y axis does not have to be calibrated, press key (15) on the
laser keypad or key (2) on the remote control to save the calibration
you have just made on X axis. The laser will shut off. If you are not
sure of the calibration and do not wish to save it, turn the laser off
with the On/Off key.
4.4 Checking Y Axis
1.
Rotate the laser 90º so that Y is facing the wall.
2.
Mark the location of the laser point on the wall.
3.
Rotate the laser 180º so that Y’ faces the wall.
4.
Mark the location of the laser point near the first mark.
5.
At 100 ft., the marks should be no more than ± 1/4” apart (at 30 m,
no more than 6 mm apart). This is within the stated accuracy of ±
1/8” at 100 ft. (± 0.01%).
6.
If the marks are close enough, Y axis is within calibration. Proceed to
“Final X to Y Check”. If the marks are not close enough, Y axis needs
to be calibrated.
4.5 Calibrating Y Axis
The laser must be calibrated to bring the beam to the center of the two
Y marks. Read “Calibration overview” before proceeding.
If you are still in calibration mode from the X axis, press key (16) on the
laser keypad or key (3) on the remote control to change to the Y axis.
When the Y LED (21) blinks slowly, it’s ready to be calibrated in Y axis.