RAMSET Viper Tool Operator's Safety & Operating Instruction Manual - Parts Listing / Maintenance
PARTS LISTING / MAINTENANCE
PARTS LISTING / MAINTENANCE
13
VIPER TOOL PARTS LIST
KEY
PART NO.
DESCRIPTION
1
MVP100A
MUZZLE BUSHING ASSEMBLY
2
MVP140
PISTON
3
MVP150
BARREL
4
MVP21A
SPRINGS (barrel, firing pin & firing pin
assembly)
5
MVP110A
BUFFER (package of 3)
6
TOOL HOUSING (not a spare part)
7
2VP18
FIRING PIN ASSEMBLY
8
MVP500AP
ADVANCE LEVER AND PIN
9
MVP600A
ADVANCE LEVER CAM AND SCREW
10
MVP028
POLE CONNECTOR
11
2VP11
LOCKOUT BALL (PKG. OF 3)
12
2VP29
HANDLE CONNECTOR
13
MVP130
RETAINING COLLAR
14
2VP30
SPALL GUARD
15
2VP33
WAVE WASHER
16
2VP3A
LINER BALLS AND SPRINGS (not
shown)
17
316540
PAWLS (package of 2)
MAINTENANCE
IMPROPERLY MAINTAINED TOOLS CAN CAUSE SEROIUS INJURIES
TO TOOL OPERATORS AND BYSTANDERS
CLEAN TOOL DAILY
Always make sure the tool is not loaded before performing any service or
repair and always wear safety goggles when cleaning or servicing the tool.
NORMAL CLEANING
All front end parts shown in the disassembly section are to be cleaned daily, or
more often if necessary, to maintain best tool function. Remove all dirt and carbon
buildup with detergent oil and wire brush and wipe parts dry with a clean rag. Check
all parts for wear or damage before reassembly and replace or repair any worn or
damaged parts.
COMPLETE CLEANING / GENERAL MAINTENANCE
Heavy use or constant exposure to dirt and debris may require that the tool be
cleaned more extensively. Complete disassembly and cleaning of all parts may be
necessary to restore the tool to normal operation. General maintenance should be
performed every six months or more often if the tool is subjected to heavy use.
Contact your authorized Ramset Distributor for assistance.
ALWAYS FUNCTION TEST THE TOOL AFTER PERFORMING ANY SERVICE.