Rancilio CLASSE 10 Technical Manual - page 12
42
9.LISTOfmALfUNcTIONS
Thesystemelectronicsarecapableofdiagnosing
thefollowingfailuresbydisplayingtherelativeerror
codesonscreen:
Becausetheyareserious,theseerrorswillstopand
blockmachineoperations.
G00 CheckCPU
G01 Watermissing
G02 BoilerPressurelow
G0 Boilerprobeshorted
G04 Interruptedboilerprobe
G05 ConnectionIDS
G06 Regen.softener
G07 Maintenance
G08 Cleaninginterrupted
G09 24VGroup1shorted
G10 24VGroup2shorted
G11 24VGroupshorted
G12 24VGroup4shorted
G1 24VFunc.Groupshorted
G14 12VCapacitivelevelshorted
G15 12VTransducershorted
G16 2VFlowmetershorted
G17 5Vextshorted
G18 12Vskpowershorted
FailuresG06-7-8-willnotblockthemachinefunctions
andaredisplayedontheerrorcodeslog..
10.LISTOfWArNING
Thesystemelectronicsarecapableofdiagnosingthe
followingfailuresbydisplayingtherelativeerrorcode
onscreen(whichwillcomeflashingonalternatively
tothecustomisationlogos).
Becausetheyarenotserious,theseerrorswillallow
themachinetokeeprunning.
Weneverthelessrecommendthatyoucontactthe
TechnicalServiceDepartmentinordertosettlethe
problemasquicklyaspossible.
W01 Interr.flowmeterGroup1
W02 Interr.flowmeterGroup2
W03 Interr.flowmeterGroup3
W04 Interr.flowmeterGroup4
W05 iSteamprobeshorted
W06 Interr.iSteamprobe
W07 Checkdata
W08 Maintenance
W09 Watersoftener
W10 Runthecoffeecleaningcycle
W11 Checktheclock
W12 EVGroup1shorted
W1 Interr.EVGroup1
W14 EVGroup2shorted
W15 Interr.EVGroup2
W16 EVGroupshorted
W17 EVGroup4shorted
W18 EVAutofillshorted
W19 Interr.EVAutofill
W20 EVHotwatershorted
W21 Interr.EVHotwater
W22 EVcold4-TEAshorted
W2 Interr.EVcold4-TEA
W24 EVhot4-TEAshorted
W25 Interr.EVhot4-TEA
W26 EVsteamiSteamshorted
W27 Interr.EVsteamiSteam
W0 EVairiSteamshorted
W1 Interr.EVairiSteam
W32 Checkthemessagefile
W CheckUSB