2.3. ASSEMBLING THE SYSTEM TO SCAN PEDESTRIANS
1. Unzip the storage bag or unlatch the hard case and remove the pieces. There will be two
vertical pillars, two foot plates, and a cross piece.
2. Attach the vertical pillars to the foot plates with the washers and wing-nuts.
3. Feed the two shorter RJ-45 cables through the crossover tube and out the small hole below the
elbow.
4. Verify that the power switch is in the "Off" position. If the system is to be operated on
batteries, install a fresh set of "D" cells at this time. Otherwise, make sure an ac power source is
available.
5. Stand the two vertical pillars upright, approximately 32" apart. Orient the pillars so that the
serial number labels are facing each other.
6. Connect the RJ-45 connectors to the mating connectors on the vertical pillars. The small hole
below the elbow of the crosspiece should face the pillar with the controller.
7. Align the vertical pillars with the cross piece and slide the cross piece down onto the vertical
pillars until it is firmly seated.
8. Connect the two RJ-45 cables to the connectors marked 1 and 2 on the controller.
9. If ac power is to be used, connect the power supply output to the corresponding connector on
the TPM Controller, and plug the power supply into an ac outlet.
10. The system may be powered up, checked out, and programmed.
11. Attach the IR to the controller backplate using the supplied wing-nuts. The IR may be
positioned to face straight across or 45 degrees down. This adjustment may be necessary to avoid
triggering on people or vehicles outside the detection portal. Even with the IR pointing 45
degrees down it may not detect a very short person or an animal such as a dog. If this situation is
encountered then the system controller may be manually put into constant occupancy by pressing
the star (*) key on the keypad. To disable constant occupancy and return the unit to normal
operation press the pound key (#) on the keypad.