Rapiscan TSA TPM-903B Operation And Service Manual - page 21
TSA TPM903 Operations and Service Manual
Doc: # 5058 Rev. A
_____________________________________________________________________________________________________________________
_____________________________________________________________________________________________________________________
This document is the exclusive property of Rapiscan Systems.
Unauthorized use or distribution is strictly prohibited
15
3.4.2.8 RESET CAL:
This routine restores the factory calibration HVDAC value. When pillar is calibrated at Rapiscan,
the HVDAC value is stored in the DM-757 in the pillar. If a calibration fails, the user may
attempt to recover by using the Reset Cal routine.
User is presented with:
RESET FACTORY
CALIBRATION
ON BOTH PILLARS
RESET: 1 ABORT: 3
If user presses 1:
The TPM controller sends a command to both pillars instructing the DM-757's to use the factory
calibration HVDAC value and presents the user with:
FACTORY
CALIBRATION
RESTORED
PRESS ANY KEY
Pressing key returns to the menu
If the user chose to abort by pressing 2, he/she is presented with:
RESET ABORTED
PRESS ANY KEY
Pressing key at this point returns to menu