3.4.2.6 PROFILING:
The controller can be set to continuously output an ASCII data string to the Ethernet and RS-232
outputs. The display will show "ON" or "OFF". Pressing any key other than the <#> key toggles
the setting. The <#> key accepts the current setting.
The strings look like this:
GB,XXXXXX,XXXXXX,XXXXXX,XXXXXX CRLF
Gamma background sent every 5 seconds. Counts are a 20 second rolling average normalized to
a one second count.
GH,XXXXXX,XXXXXX,XXXXXX,XXXXXX CRLF
Gamma high background fault sent every 5 seconds for the duration of the fault condition.
GL,XXXXXX,XXXXXX,XXXXXX,XXXXXX CRLF
Gamma low background fault sent every 5 seconds for the duration of the fault condition.
GS,XXXXXX,XXXXXX,XXXXXX,XXXXXX CRLF
TCP Ethernet output: Raw gamma count information sent every 200msec while the system is
occupied and not in an alarm condition.
RS-232 Output: Sent every second while the system is occupied and not in an alarm condition.
The counts are a one second count averaged from the 200msec rolling count buffer.
GA,XXXXXX,XXXXXX,XXXXXX,XXXXXX CRLF
TCP Ethernet output: Raw gamma count information sent every 200msec while the system is
occupied and in an alarm condition.
RS-232 Output: Sent every second while the system is occupied and in an alarm condition. The
counts are a one second count averaged from the 200msec rolling count buffer.
TT,000000, 000000, 000000, 000000 CRLF
Tamper or power fail condition detected. This is sent once when the following conditions occur;
ac power loss, charger output failure, or when the pillar doors are open. Fields are padded to 32
bytes.
TC, 111111,111111,111111,111111 CRLF
Tamper or power fail condition cleared. This is sent once when the following conditions occur;
ac power returned, or when the pillar doors are closed. Fields are padded to 32 bytes.
GX,XXXXXX,000000,000000,000000 CRLF
System occupancy count since midnight each day. xxxxxx = 1 – 99,9999 occupancies. This
message is sent with an incremented count every time the pillar clears the occupancy. This
variable is automatically cleared on a power cycle and at midnight each day. Fields are padded
for 32 bytes.